APAR status
Closed as unreproducible in next release.
Error description
PMG/TOOL NAME CHANGE DOES NOT CHANGE IN COPY-TRANSFORMATION .
Local fix
Problem summary
PMG/TOOL NAME CHANGE DOES NOT CHANGE IN INDEX/COPY PMG/TOOL NAME CHANGE DOES NOT CHANGE IN COPY-TRANSFORMATION .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 11. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 13 GA level Incident Diagnosis The problem is not reproduced in R13 since a R13 development has change the behaviour for this specific kind of Copy Transformation. The scenario now works like the customer has expected it to work. Reason This CopyTransformation is only having a Tool Path as reference (Not a MO): no MO list is displayed in the definition panel. It have been created using: - Tool Path Editor and Cut Command, OR - V5R8 or V5R9 and selecting more than one MO as reference. OR - V5R8 or V5R9 and the referenced MO has been deleted. Before R13: On this kind of Copy Transformation, changing the tool link to it was not allowed. mofiing the name of the tool create in the Tool change definition panel + enter create a new ressource and set it to all MOs except Copy Transformation of this kind. From R13: On this kind of Copy Transformation, changing the tool link to it is now allowed. A Tooling tab page have been had in its definition panel. So the customer scenario now works ! But the customer needs to be very careful: the reference tool path have been computed with another tool, if the geometry of the tool is modified, it is of it's responsability to check the integrity of the milling ... On other Copy Transformation (displaying a MO list in the definition panel), the tool is still defined by the tool used by its referenced Mos. .
APAR Information
APAR number
HD10241
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
511
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-08-21
Closed date
2003-08-22
Last modified date
2003-08-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R511 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"511","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
22 August 2003