APAR status
Closed as program error.
Error description
- Open .CATAnalysis - Select "Virtual Bolt Tightening" - Select General Analysis Connection.1 ==> It is selected - Double Click "Product2" and enter Analysis Connections workbench. - Create another General Analysis Connection on one of the rest two holes First Component: Cover Hole's inner surface Second Component: Tank Hole's inner surface OK - Change to GPS Analysis workbench - Select "Virtual Bolt Tightening" - Select General Analysis Connection.3 you just created. ==> Not selectable!!! ==> This happens with Virtual Spring Bolt Tightening, too. ==> This happens with Face Face Connection, too. ■3 Workaround Save the Assembly and close it and re-open it. .
Local fix
Problem summary
Distaqnce Connection or Face-toFace Connection in Analysis co nnection not selectable with Virtual Bolt Tightening - Open .CATAnalysis - Select "Virtual Bolt Tightening" - Select General Analysis Connection.1 ==> It is selected - Double Click "Product2" and enter Analysis Connections workbench. - Create another General Analysis Connection on one of the rest two holes First Component: Cover Hole's inner surface Second Component: Tank Hole's inner surface OK - Change to GPS Analysis workbench - Select "Virtual Bolt Tightening" - Select General Analysis Connection.3 you just created. ==> Not selectable!!! ==> This happens with Virtual Spring Bolt Tightening, too. ==> This happens with Face Face Connection, too. 3 Workaround Save the Assembly and close it and re-open it. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev el. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R12SP04. Incident Diagnosis An error occured when we tested the validity of an analysis connection as support of a virtual bolt tightening property. We unfairly prevented the selection of a valid analysis connection. Correction Explanation none Answer and By-Pass none .
Temporary fix
Comments
APAR Information
APAR number
HD10046
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-08-13
Closed date
2003-11-13
Last modified date
2003-12-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R512 PSN SP51204
UP03/12/18 I 1000
R513 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"511","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
18 December 2003