IBM Support

HD09092: "RESULTS DATA" & "COMPUTATION DATA" CANNOT BE SELECTED EACH FO LDERS BY THE STORAGE LOCATION ICON

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1.Open A.CATAnalysis.
    2.Select Storage Location icon.
    3.Change the location for Results Data
    to "C:B%Temp".
    4.Change the location for Computation Data
    to "D:B%Temp".
    => The setting at previous step is ignored and the
    location for Result
    Data is also changed to "D:B%Temp".
    Remark:The workaround for this issue is to re-
    select by double-click on Results in the specification
    tree.
    
    
    
    .
    

Local fix

Problem summary

  • "Results Data" & "Computation Data" cannot be selected each  fo
    lders by the Storage Location icon
    1.Open A.CATAnalysis.
    2.Select Storage Location icon.
    3.Change the location for Results Data
    to "C:B%Temp".
    4.Change the location for Computation Data
    to "D:B%Temp".
    => The setting at previous step is ignored and the
    location for Result
    Data is also changed to "D:B%Temp".
    Remark:The workaround for this issue is to re-
    select by double-click on Results in the specification
    tree.
    
    
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev
    el.
    
    Incident Diagnosis
    Results Data" & "Computation Data" cannot be selected each fold
    ers by the Storage Location icon
    
    
    Correction Explanation
    code correction
    
    Answer and By-Pass
    use same drive
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD09092

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-07-15

  • Closed date

    2003-10-20

  • Last modified date

    2003-10-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R512 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
20 October 2003