Error description

  • Automatic centerline of a circle is too short to
    deal with
    The length of Center Line is not long enough
    for a small circle.
    When creating Center Line of circle with "Center
    Line" command, its length is defined automatically
    by CATIA in proportion to the radius of circle.
    
    The part of Center Line going out of the circle
    should be longer than the current one.
    
    To be able to specify the overrun by default for
    the center lines created manually or automatically
    is possible in V5R11 using styles.
    But today there is a bug and it is the reason why
    this apar is created.
    
    
    .
    

Local fix

Problem summary

  • The length of Center Line is not long enough
            for a small circle
    Automatic centerline of a circle is too short to
    deal with
    The length of Center Line is not long enough
    for a small circle.
    When creating Center Line of circle with "Center
    Line" command, its length is defined automatically
    by CATIA in proportion to the radius of circle.
    
    The part of Center Line going out of the circle
    should be longer than the current one.
    
    To be able to specify the overrun by default for
    the center lines created manually or automatically
    is possible in V5R11 using styles.
    But today there is a bug and it is the reason why
    this apar is created.
    
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 12 GA lev
    el.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP05.
    
    Incident Diagnosis
    Generated centerlines do not take into account
    OverRunLength style parameter. Therefore, any
    specification of this length in the standard xml file
    is useless, and the user is not able to define a
    default value.
    
    Correction Explanation
    OverRunLength style parameter defined in standard xml file will
     be taken into acount by Generated centerlines.
    
    Answer and By-Pass
    With this correction, user will be able to set a default value
    for the generated centerlines in the xml standard file : this p
    arameter will be taken into account.
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD09077

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-07-15

  • Closed date

    2003-08-14

  • Last modified date

    2003-09-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R510 PSN

       UP

  • R511 PSN SP51105

       UP03/09/16 I 1000