HD07430: ITEV5CV5 : DUPLICATION OF EXISTING PART WITH í ù IN LCA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • ITEV5CV5 : DUPLICATION OF EXISTING PART WITH ■  IN LCA
    
    SCENARIO :
    -----------------
    Legend : COMPx are ENOVIA LCA part reference object.
             PARTx  are ENOVIA LCA part reference object with a
    CATPart document as representation.
    
    1) In ENOVIA LCA  create an empty PRC '2D_PRODUCT_COMP1'
    2) In ENOVIA LCA  create the following PRC 'ASSEMBLY'
    Exploded LCA Structure :PRC 'ASSEMBLY'
    PRC
      |_ COMP1
      |   |_ COMP2
      |   |     |_ PART1
      |   |     |_ PART2
      |   |_ COMP3
      |        |_ PART3
      |        |_ PART4
      |_ COMP4
    
    2) From LCA  load the assembly COMP1 (for which cust wants
    to create an assembly drawing) in CATIA V5.
    CATIA V5 PRC window session:
    PRC
      |_ COMP1
         |_ COMP2
         |     |_ PART1
         |     |_ PART2
         |_ COMP3
              |_ PART3
              |_ PART4
    
    3) From ENOVIA LCA, load the empty PRC '2D_PRODUCT_COMP1'
    4) In CATIA V5 PRC window copy the COMP1 assembly and paste
    it (break links) under the CATProduct  '2D_PRODUCT_COMP1'.
    
    CATA V5 2D_PRODUCT_COMP1 window session:
    2D_PRODUCT_COMP
      |_ COMP1
         |_ COMP2
         |     |_ PART1
         |     |_ PART2
         |_ COMP3
              |_ PART3
              |_ PART4
    5) From CATIA V5, save the CATProduct (2D_PRODUCT_COMP1) in
    ENOVIA LCA.
    
    2D_PRODUCT_COMP1 to which
    the .CATProduct document is attached. ---> OK
    -COMP1, COMP2 & COMP3 are duplicated in LCA (with ■1 added
    to thier part number). ---> KO
    -PART1, PART2, PART3,  &  PART4 are not duplicated. ---> OK
    
    EXPECTED RESULT :
    ---------------
    - Since COMP1, COMP2 & COMP3 were loaded from ENOVIA, the
    system must not recreate them  with ■1 at the saving of the
    product (2D_PRODUCT_COMP1). The behavior should be the same
    as the PART1, PART2, PART3,  &  PART4.
    

Local fix

Problem summary

  • DUPLICATION OF EXISTING PART WITH 0 ' IN LCA
    *DS
    JQD on 04 Jun.
    ===============
    
    
    
    
    
    <table border="0" cellSpacing="0"><tr><td  class="tdComment">De
    scription</td></tr></table> ===================================
    ===============================
     |                       INFORMATIONS FOR AIX OS
    
     ==============================================================
    ====
    *DESCRIPTION
    
    ITEV5CV5 : DUPLICATION OF EXISTING PART WITH     IN LCA
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN ENOVIA.
    
    These are the reasons of the PRS part:
    
    This is the intended behaviour in V5
    - On a Paste Break Link, the new entity is created
    for the topmost here COMP1
    - This creation of new entities is extended to
    embedded component, here COMP2
    - But the creation of new entities is not expended
    to other sub entities if they have a stand alone
    definition. Hence a new part is not created for
    PART1. And if COMP2 was a product and a
    component, COMP2 would not be created new
    either.
    
    There is no other solution than that as long as you
    are using components. This because a component
    defined in the product PRC can not be instanciated
    in anothe product, here 2D_PRC.
    
    
    That's why it may be considered FIN and fixed in
    R12 With the "Elementary Part" developement in R12, assemblies
    created as CATProduct in CATIA and saved exploded in ENOVIA are
     restored as
    CATProduct in CATIA (in R10 / R11 they come
    back as CATComponent).
    
    This will let you share product between the 2 distinct PRC by a
     simple Copy / Paste (without
    break link)
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD07430

  • Reported component name

    ENOVIA LCA AIX

  • Reported component ID

    569101700

  • Reported release

    510

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-06-04

  • Closed date

    2003-06-19

  • Last modified date

    2006-04-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDJRN","label":"ENOVIA LCA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
20 April 2006