APAR status
Closed as program error.
Error description
DESCRIPTION: Incorrect IGES line thickness for very thin lines STEP BY STEP SCENARIO: 1. Run CATIA V5 in admin mode 2. Tools / Standard 3. Category : Drafting 4. Select ISO 5. Go to Linethickness 6. In the 1 change 0.13 to 0.01 7. New Drawing 8. Create simple line 9. Select 0.01 as the line width 10. Save is as IG2 11. Open the IGES file with text editor 12. Note that Global paramter 16 = 2000 13. Note that Global paramter 17 = 2 14. Note that line width for element 110 is 50. 15. Therefore the linewidth of the line is 0.05 instead of 0.01 -> this is the problem .
Local fix
Problem summary
Incorrect IGES line thickness for very thin lines DESCRIPTION: Incorrect IGES line thickness for very thin lines STEP BY STEP SCENARIO: 1. Run CATIA V5 in admin mode 2. Tools / Standard 3. Category : Drafting 4. Select ISO 5. Go to Linethickness 6. In the 1 change 0.13 to 0.01 7. New Drawing 8. Create simple line 9. Select 0.01 as the line width 10. Save is as IG2 11. Open the IGES file with text editor 12. Note that Global paramter 16 = 2000 13. Note that Global paramter 17 = 2 14. Note that line width for element 110 is 50. 15. Therefore the linewidth of the line is 0.05 instead of 0.01 -> this is the problem .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev el. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R12SP01. THERE WAS A PROBLEM IN THE CODE THAT IS NOW FIXED. THE LINEWIDTH IS NOW CORRECTLY EXPORTED TO THE GOOD VALUE INTO THE IGES 2D FILE. .
Temporary fix
Comments
APAR Information
APAR number
HD07363
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-06-03
Closed date
2003-08-11
Last modified date
2003-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R510 PSN
UP
R511 PSN
UP