IBM Support

HD06194: STEP / CATIA ABEND WHEN LARGE STEP DATA IMPORT IS PERFORMED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CATIA ABEND when large STEP data Import.
    .
    
    <Scenario>
    
    1.Open "500N.stp".
    
    => CATIA ABEND without any trace.
    
    .
    

Local fix

Problem summary

  • STEP / CATIA ABEND WHEN LARGE STEP DATA IMPORT IS PERFORMED
    CATIA ABEND when large STEP data Import.
    .
    
    <Scenario>
    
    1.Open "500N.stp".
    
    => CATIA ABEND without any trace.
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 13 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R12SP05.
    .
    Note : it is fixed from V5R12 SP02.
    .
    Incident Diagnosis
    CATIA Abend in case of huge step files are
    imported.
    .
    Correction Explanation
    System goes out of memory ; problem occured
    then in the SDAI memory
    allocator and lead to crash. CATIA now stops
    reading the file if a
    call fails in the allocator.
    .
    Answer :
    A window appears now with " Invalid input file.
    Transfer aborted " message and crash no longer
    occurs because of
    memory.
    Moreover, in the .err text file, a "not sufficient
    memory" message
    is also displayed.
    Please note that the step file is too big to be
    imported into CATIA.
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD06194

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-04-18

  • Closed date

    2003-12-15

  • Last modified date

    2004-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R511 PSN

       UP

  • R512 PSN SP51205

       UP04/02/03 I 1000

  • R513 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: