APAR status
Closed as program error.
Error description
PARTDESIGN / ERROR ON A DRAFT REFLECT LINE CREATION : MULTI RIBBON OPERATOR ERROR OCCURS . SCENARIO : --------- 1. open attached CATPart 2. Create a Draft reflect line : - sel the cylindrical face. - Angle : 0.5 - Define parting element : sel zx plane. OK 3. Create another Draft reflect line : - Sel the other "side" of the cylindrical face. => There is a message : the face is already drafted but you can draft it again => OK button. - Define the parting element : sel zx plane and invert the arrow if necessary. - Click on OK. . ==> Multi ribbon error : a single operation cannot process more than one ribbon. . Note that this operation can be processed with CATIA V4. . There are several by-pass (that are not industrial) : 1. the circle that is used to generate the pad can be made in 2 parts in the sketcher. 2. before drafting the pad, you can apply a thickness on the pad. Then, you create the 2 drafts and then you apply the negative thickness. .
Local fix
Problem summary
PARTDESIGN / ERROR ON A DRAFT REFLECT LINE CREATION : MULTI RIB BON OPERATOR ERROR OCCURS PARTDESIGN / ERROR ON A DRAFT REFLECT LINE CREATION : MULTI RIB BON OPERATOR ERROR OCCURS .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 12 GA lev el. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP04 . . Incident Diagnosis After a first ReflectLine Draft has been applied on one side of a cylinder with respect to a given parting element, it is impossible to generate the second Draft on the other side. . Correction Explanation This is due to the small angle value that permits the first Draft to be generated without the creation of a step face based on the parting element. . This is why it is impossible to distinguish between the two cylinder faces on the resulting body. . Therefore, when selecting the face to be drafted for the second operation, both cylinder faces are selected (even though they aren't connected). . Since the Draft algorithm attempts to initalize ribbons on all separate selected faces, the operation fails in this case because the ReflectLine cannot be computed on the already drafted cylinder face. . Answer : This APAR is PER because error message has been enhanced : The operation now generates a more appropriate error message that also shows in red the location of the select ed face for which no initial result could be computed. . Concerning second draft creation, the answer is it's a suggesti on SUG : In order to solve this problem, it would be necessary to make it possible to select only one side of the cylinder in the interface of the Draft feature ; this is an important development which can only be ha ndled as enhancement request. .
Temporary fix
Comments
APAR Information
APAR number
HD05139
Reported component name
CATIA V 5 SUN
Reported component ID
569104000
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-03-19
Closed date
2003-07-08
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V 5 SUN
Fixed component ID
569104000
Applicable component levels
R510 PSN
UP
R511 PSN SP51104
UP03/08/04 N 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: