  • Scenario 1: (Unsuccessful case)
    Workbench: GSD
    1. OPEN   TO0019.CATPart
    2. Menu  Insert / Operations / Join
    3. Select  the Surface.1 and the Fillet.1
    4. Press OK
    5. The update error appears: "Join.1: Invalid Value for
    object type"
    .
    Scenario 2: (Successful case)
    6. Make show the Surface.2 and the Surface.3 and then Hide
    the Fillet.1
    7. Select Surface.1 and Surface.2 as joined elements
    8. Press OK
    9. Joined surface is created
    10. Select menu  Insert / Operations / Shape Fillet
    11. Select Join.1 as the element of Support 1
    12. Select Surface.3 as the element of Support 2
    13. Key in 5.7mm for the Radius
    14. Select both arrows and make them opposite direction
    15. Press OK
    16. Fillet.2 is created successfully.The bottom line is
    that if you do JOIN first and then Fillet,the result is
    successful. But it is not vise versa.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
       ====> GSD : UNABLE TO JOIN THE SURFACES
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    
    
    
     TECHNICAL EXPLANATION FOR THE RESTRICTION:
       ====>there is a corrupted surface,
       ====>the error message is also justified
    
    
    
     BY-PASS:
       ====>apply the healing function to this corrupted surface
       ====>before doing the Join
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD03853

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    509

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-02-12

  • Closed date

    2003-03-04

  • Last modified date

    2003-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"509","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 March 2003