  • *Model dependent*
    .
    SCENARIO :
    ---------
    1> Open "F51_new.CATPART".
    2> Click "Shape_Fillet" icon.
    3> Select Support1 "Extract.5".
       Select Support2 "Extract.6".
       Set value of the radius to 10mm.
       Select Extremities "Maximum".
    4> Click "OK" in "Fillet Definition" panel.
    ==> "Update Error" is displayed.
    "Fillet_1:
    Fillet cannot be initialized : modify radius or supports.
    Each support must be continuous (tangency).
    Multi-ribbon fillets are not yet allowed."
    .
    The "Shape_Fillet" is not created.
    .
    Remark: with 7mm radius, fillet is created.
    

Local fix

Problem summary

  • GSD - SHAPE FILLET IS NOT CREATED WITH 10MM RADIUS :' FILLET CA
    NNOT BE INITIALIZED ' ERROR OCCURS
    GSD - SHAPE FILLET IS NOT CREATED WITH 10MM RADIUS :' FILLET CA
    NNOT BE INITIALIZED ' ERROR OCCURS
    
    
    .
    

Problem conclusion

  • INCIDENT DIAGNOSIS:
    GSD - SHAPE FILLET IS NOT CREATED WITH 10MM RADIUS :' FILLET
    CANNOT BE INITIALIZED ' ERROR OCCURS
    .
    TECHNICAL EXPLANATION FOR THE CORRECTION:
    For this given radius, twist problem occurs at shape fillet
    creation.
    Before this PER correction, initialization of fillet was not
    possible on a twisted solution in case it was the only
    detected solution.
    Here only twist is detected, initialization computation
    is now possible with the correction.
    But there is still twist problem, which is expected with 10mm
    radius ; new error message appears about this twist problem.
    .
    ANSWER AND POSSIBLE BY-PASS:
    Problem is closed PER since error message has been modified.
    Concerning the twist problem, it cannot be avoided :
    decrease radius to enable the fillet creation.
    
    PROBLEM CONCLUSION:
    THIS PROBLEM WILL BE FIXED ON
    CATIA VERSION 5 RELEASE 12 GA level
    NOTE THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP02
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD03325

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-01-28

  • Closed date

    2003-07-16

  • Last modified date

    2009-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R510 PSN

       UP

  • R511 PSN SP51102

       UP03/06/06 N 1000