Error description
*Model dependent* . SCENARIO : --------- 1> Open "F51_new.CATPART". 2> Click "Shape_Fillet" icon. 3> Select Support1 "Extract.5". Select Support2 "Extract.6". Set value of the radius to 10mm. Select Extremities "Maximum". 4> Click "OK" in "Fillet Definition" panel. ==> "Update Error" is displayed. "Fillet_1: Fillet cannot be initialized : modify radius or supports. Each support must be continuous (tangency). Multi-ribbon fillets are not yet allowed." . The "Shape_Fillet" is not created. . Remark: with 7mm radius, fillet is created.
Local fix
Problem summary
GSD - SHAPE FILLET IS NOT CREATED WITH 10MM RADIUS :' FILLET CA NNOT BE INITIALIZED ' ERROR OCCURS GSD - SHAPE FILLET IS NOT CREATED WITH 10MM RADIUS :' FILLET CA NNOT BE INITIALIZED ' ERROR OCCURS .
Problem conclusion
INCIDENT DIAGNOSIS: GSD - SHAPE FILLET IS NOT CREATED WITH 10MM RADIUS :' FILLET CANNOT BE INITIALIZED ' ERROR OCCURS . TECHNICAL EXPLANATION FOR THE CORRECTION: For this given radius, twist problem occurs at shape fillet creation. Before this PER correction, initialization of fillet was not possible on a twisted solution in case it was the only detected solution. Here only twist is detected, initialization computation is now possible with the correction. But there is still twist problem, which is expected with 10mm radius ; new error message appears about this twist problem. . ANSWER AND POSSIBLE BY-PASS: Problem is closed PER since error message has been modified. Concerning the twist problem, it cannot be avoided : decrease radius to enable the fillet creation. PROBLEM CONCLUSION: THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 12 GA level NOTE THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP02 .
Temporary fix
Comments
APAR Information
APAR number
HD03325
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-01-28
Closed date
2003-07-16
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R510 PSN
UP
R511 PSN SP51102
UP03/06/06 N 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
24 June 2009