IBM Support

HD02142: SPECIAL CHARACTERS PRINT INCORRECTLY: DIAMETER SYMBOL IS SHIFTED IE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABSTRACT:  Special Characters Print Incorrectly
    Problem:
    Have a text box with special characters from the "insert
    symbol" box. The symbols include degree (ᆰ) and others.  The
    text box appears correct on the screen, but when it is
    printed, the text is shifted and large amount of space is
    put between characters and the special symbols that have
    been used from the Catia insert symbol box.
    

Local fix

Problem summary

  • SPECIAL CHARACTERS PRINT INCORRECTLY
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    ABSTRACT:  Special Characters Print Incorrectly
    
    Problem:
    
    Have a text box with special characters from the "insert
    
    symbol" box. The symbols include degree (ª) and others.  The
    
    text box appears correct on the screen, but when it is
    
    printed, the text is shifted and large amount of space is
    
    put between characters and the special symbols that have
    
    been used from the Catia insert symbol box.
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev
    el.
    
    Incident Diagnosis
    Problem with anchor point of TTF Fonts.
    The problem was due to incorrect bounding box
    values.
    
    Correction Explanation
    The Bouding box errors was happening because of
    incorrect values of box 1  which is a member of
    CATTrueTypeFont class, which was being created
    as decent - internalLeading.
    
    Answer and By-Pass
    The correction involved changing Box 1  to
    ascent - descent. This enables windows sdk
    functions to return the correct values for the
    bounding box.
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD02142

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-12-18

  • Closed date

    2003-10-31

  • Last modified date

    2004-03-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R512 PSN

       UP