APAR status
Closed as unreproducible in next release.
Error description
TEAM PDM: When executing "Replace with Selected Revision" operation on a part for the SECOND time the part does not get updated and part's properties also do not get updated. Scenario: 1) Create Assembly with one Part (a cube) in it. Check in both of them to Smarteam. 2) User One checks out Assembly and copies out the Part by doing teampdm/File Operation 3) User Two (at a different computer) checks out Part for editing, modifies it (make a visibly large hole in the cube) and checks back in 4) User One in his session of CATIA selects Part, goes to TeamPDM->LifeCycle and selects "Replace with Selected Revision". In pop up window User One selects latest revision of the Part (rev a.0) 5) Part is updated on the screen in CATIA.(you can see the hole in the cube) 6) User One performs TeamPDM->Save on the Assembly. 7) User One again tries to replace the part with the latest revision 7.a Select Part in CATIA tree 7.b From TeamPDM->LifeCycle select "Replace with Selected Revision" 7.c From the popped up window select previous revision (blank revision), click OK =>The model did not get updated with the older part (you can still see the hole, even though you should not) Also the CATIA Properties of the part did not get updated. The revision property still has value a.0, even though its value should be blank.
Local fix
Problem summary
INCIDENT DIAGNOSIS: Problem in the command UnloadReload of Team PDM TECHNICAL EXPLANATION FOR THE CORRECTION: Creatio n of a temporary file , then replacement of this file by the selected document in the database. During the second replacement, we can not do a save as of the selecte d document because the first temporary file is still in sess ion. This is now corrected. ANSWER AND POSSIBLE BY-PASS: By-pass : do a replace component with the Product Structure command REMARK: Do not forget to unselect in tools/Administrator options /Life cycle options/out of vault tab the following option Last Revision policy for overwrite local files upon Check Copy otherwise you won t be able to perform the operation
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 9 . THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 11 GA level AND ON V5R10SP02 AND V5R9SP06. Comment: note that this problem is also unreproducible on V5R9 SP 5 and V5R10 SP1
APAR Information
APAR number
HC98500
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
509
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-09-17
Closed date
2002-12-02
Last modified date
2009-06-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R509 PSN SP50906
UP02/12/12 N 1000
R510 PSN SP51002
UP03/01/15 N 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"509","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
23 June 2009