HC98500: TEAM PDM: REPLACE WITH SELECTED REVISION FOR THE SECOND TIME DOES NOT UPDATE THE PART NOR ITS PROPERTIES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • TEAM PDM: When executing "Replace with Selected Revision"
    operation on a part for the SECOND time the part does not
    get updated and part's properties also do not get updated.
    
    Scenario:
    1) Create Assembly with one Part (a cube) in it. Check in
    both of
    them to Smarteam.
    2) User One checks out Assembly and copies out the Part by
    doing teampdm/File Operation
    3) User Two (at a different computer) checks out Part for
    editing,
    modifies it (make a visibly large hole in the cube) and
    checks back
    in
    4) User One in his session of CATIA selects Part, goes to
    TeamPDM->LifeCycle and selects "Replace with Selected
    Revision". In pop up window User One selects latest revision
    of the Part (rev a.0)
    5) Part is updated on the screen in CATIA.(you can see the
    hole in the cube)
    6) User One performs TeamPDM->Save on the Assembly.
    7) User One again tries to replace the part with the latest
    revision
            7.a Select Part in CATIA tree
            7.b From TeamPDM->LifeCycle select "Replace with
    Selected Revision"
            7.c From the popped up window select previous
    revision (blank revision), click OK
    =>The model did not get updated with the older part (you can
    still see the hole, even though you should not)
    Also the CATIA Properties of the part did not get updated.
    The revision property still has value a.0, even though its
    value should be blank.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
     Problem  in the command UnloadReload of Team PDM
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
     Creatio n of a temporary file , then replacement of this file
     by the  selected document in the database.
     During  the second replacement, we can not do a save as of the
     selecte d document because the first temporary file is still
     in sess ion. This is now corrected.
    
     ANSWER AND POSSIBLE BY-PASS:
     By-pass : do a replace component with the Product Structure
     command
    
     REMARK:
     Do not forget to unselect in  tools/Administrator options
     /Life cycle options/out of vault tab  the following option
      Last Revision policy for overwrite local files upon Check
     Copy  otherwise you won t be able to perform the operation
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
        CATIA VERSION 5 RELEASE 9
    .
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
        CATIA VERSION 5 RELEASE 11 GA level AND ON V5R10SP02 AND
     V5R9SP06.
    
     Comment: note that this problem is also unreproducible on
     V5R9 SP 5 and V5R10 SP1
    

APAR Information

  • APAR number

    HC98500

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    509

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-09-17

  • Closed date

    2002-12-02

  • Last modified date

    2009-06-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R509 PSN SP50906

       UP02/12/12 N 1000

  • R510 PSN SP51002

       UP03/01/15 N 1000