  • SCENARIO FROM SCRATCH :
    -----------------------
    1) Open new part and create sketch
    2) Make two distinct circles(`circle.1`and `circle.2`)
    3) Create Constraint with `coincidence` between the center
    of `circle.1` and `circle.2` ; OK
    4)  Create Constraint with `concentricity` by selecting
       the arc of the circle of `circle.1`and `circle.2` ; OK
    -->  `coincidence` and `concentricity` should be
    overdefined.
    .
    For instance, by creating a distance constraint of 0mm
    instead of coincidence constraint at Step.3, the sketch
    cannot be updated correctly, and constraints are seen
    overdefined as expected.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    Concentricity between circles and coincidence between circles
     centersare not over defined .
    .
     TECHNICAL EXPLANATION FOR THE RESTRICTION:
    The variational solver used by Sketcher is able to analyse the
    constraint schema and it doesn't set the geometrical
    constraintsas over-defined if the system is consistent
    (constraints verified).
    .
    This capability is available for geometrical constraints
    (parallel, perpendicular, coincidence,...) but not for
    dimensional constraints (length, distance, angle).
    .
    In this case, having over-constraint with a distance
    constraint of 0mm and having no over-constraint with a
    coincidence constraint is the right behaviour.
    
     BY-PASS:
    It's a very powerful behaviour that the system automatically
    avoid over-constraints when the geometrical constraint (not
    dimensional) specifications are consistent (verified).
    This capability allows you today to put a distance between
    two vertical lines or a distance between two parallel lines
    for example.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC95142

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    508

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-06-17

  • Closed date

    2002-06-19

  • Last modified date

    2002-06-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"508","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
19 June 2002