APAR status
Closed as Permanent restriction.
Error description
SCENARIO FROM SCRATCH : ----------------------- 1) Open new part and create sketch 2) Make two distinct circles(`circle.1`and `circle.2`) 3) Create Constraint with `coincidence` between the center of `circle.1` and `circle.2` ; OK 4) Create Constraint with `concentricity` by selecting the arc of the circle of `circle.1`and `circle.2` ; OK --> `coincidence` and `concentricity` should be overdefined. . For instance, by creating a distance constraint of 0mm instead of coincidence constraint at Step.3, the sketch cannot be updated correctly, and constraints are seen overdefined as expected.
Local fix
Problem summary
INCIDENT DIAGNOSIS: Concentricity between circles and coincidence between circles centersare not over defined . . TECHNICAL EXPLANATION FOR THE RESTRICTION: The variational solver used by Sketcher is able to analyse the constraint schema and it doesn't set the geometrical constraintsas over-defined if the system is consistent (constraints verified). . This capability is available for geometrical constraints (parallel, perpendicular, coincidence,...) but not for dimensional constraints (length, distance, angle). . In this case, having over-constraint with a distance constraint of 0mm and having no over-constraint with a coincidence constraint is the right behaviour. BY-PASS: It's a very powerful behaviour that the system automatically avoid over-constraints when the geometrical constraint (not dimensional) specifications are consistent (verified). This capability allows you today to put a distance between two vertical lines or a distance between two parallel lines for example.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
Temporary fix
Comments
APAR Information
APAR number
HC95142
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
508
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-06-17
Closed date
2002-06-19
Last modified date
2002-06-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"508","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
19 June 2002