HD60927: ASMD : SKETCH : SKETCH CONSTRAINTS FAILS ON EDITING A SKETCH FR OM WEB CREATED ON R12

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • ASMD : SKETCH : SKETCH CONSTRAINTS FAILS
    ON EDITING A SKETCH FROM WEB CREATED ON
    R12
    .
    SCENARIO:
    1- Open provided CATPart.
    2- Activate AeroSpace Sheetmetal Workbench.
    3- Edit Sketch.1 into Web.1. Sketcher workbench
    appears.
    4- Create and delete a point.
    5- Exit from Sketch.
    6- Update is necessary.
    .
    OBSERVATION
    This sketch is either over-constrained or
    inconsistent. Prior to editing this sketch, you can
    use Tools>Sketch Analysis>Diagnostic to know
    which sketch element causing troubles.
    .
    

Local fix

Problem summary

  • ASMD : SKETCH : SKETCH CONSTRAINTS FAILS ON EDITING A SKETCH FR
    OM WEB CREATED ON R12
    ASMD : SKETCH : SKETCH CONSTRAINTS FAILS
    ON EDITING A SKETCH FROM WEB CREATED ON
    R12
    .
    SCENARIO:
    1- Open provided CATPart.
    2- Activate AeroSpace Sheetmetal Workbench.
    3- Edit Sketch.1 into Web.1. Sketcher workbench
    appears.
    4- Create and delete a point.
    5- Exit from Sketch.
    6- Update is necessary.
    .
    OBSERVATION
    This sketch is either over-constrained or
    inconsistent. Prior to editing this sketch, you can
    use Tools>Sketch Analysis>Diagnostic to know
    which sketch element causing troubles.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    .
    Incident Diagnosis
    Sketch constraint fails on update
    .
    Restriction Explanation
    Problem already handled.
    .
    By-Pass
    None
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD60927

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-01-17

  • Closed date

    2007-01-29

  • Last modified date

    2007-01-29