HD60896: PART / LINK IS BROKEN WHEN DRAG/DROP.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PART / LINK IS BROKEN WHEN DRAG/DROP.
    .
    SCENARIO:
    1) start Catia V5 R16 SP05 HF07
    make sure that the option "Enable Drag Drop for
    Cut, Copy,
    Paste use." is switched to on (in tab "General" of
    Tools .
    Options )
    2) open BROKEN_CCP-
    LINK_OF_PUBLISHED_PARAMETERS.CATPart
    3)create a new CATPart document.
    4)select Window. Tile Vertically
    5) switch to the sent CATPart
    6) select the Publication ""String.1""
    7) choose MB3 --> Copy
    8) switch into your new CATPart
    9) paste this published Parameter with the option
    As Result
    With Link ( MB3 --> Paste Special... )
    10)switch into the sent CATPart
    11)edit parameter of the original one in the sent
    CATPart,
    like described in sent 'Broken_CCP-Link_2.jpg'
    12)The new CATPart detects the change, demands
    from an Update
    and after that the linked Parameter will be
    synchronize ᄄ
    13)switch again into the new CATPart
    14) select the linked Parameter and try to drag it
    with MB1
    result
    - the link of the Parameter has been broken
    - the information in the Bracket has been lost
    - and Edit .Links... declares that there are no
    external
    links anymore .
    .
    .
    

Local fix

Problem summary

  • PART / LINK IS BROKEN WHEN DRAG/DROP.
    PART / LINK IS BROKEN WHEN DRAG/DROP.
    .
    SCENARIO:
    1) start Catia V5 R16 SP05 HF07
    make sure that the option "Enable Drag Drop for
    Cut, Copy,
    Paste use." is switched to on (in tab "General" of
    Tools .
    Options )
    2) open BROKEN_CCP-
    LINK_OF_PUBLISHED_PARAMETERS.CATPart
    3)create a new CATPart document.
    4)select Window. Tile Vertically
    5) switch to the sent CATPart
    6) select the Publication ""String.1""
    7) choose MB3 --> Copy
    8) switch into your new CATPart
    9) paste this published Parameter with the option
    As Result
    With Link ( MB3 --> Paste Special... )
    10)switch into the sent CATPart
    11)edit parameter of the original one in the sent
    CATPart,
    like described in sent 'Broken_CCP-Link_2.jpg'
    12)The new CATPart detects the change, demands
    from an Update
    and after that the linked Parameter will be
    synchronize
    13)switch again into the new CATPart
    14) select the linked Parameter and try to drag it
    with MB1
    result
    - the link of the Parameter has been broken
    - the information in the Bracket has been lost
    - and Edit .Links... declares that there are no
    external
    links anymore .
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    .
    Incident Diagnosis
    PART / LINK IS BROKEN WHEN DRAG/DROP.
    Correction Explanation
    The drag and drop of external parameters is now
    corrected to avoid such manipulation mistakes.
    Answer and By-Pass
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD60896

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-01-16

  • Closed date

    2007-03-12

  • Last modified date

    2007-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: