APAR status
Closed as documentation error.
Error description
GSD : GEOMETRICAL SET CAN NOT BE SELECTED AS ELEMENT OF TRANSLATE OPERATION WITH DATUM . Scenario 1. Start CATIA V5R17SP2. 2. Open Product1.CATProduct 3. Change current to Part.2. (WorkBench: Generative Shape Design) 4. Click to Create Datum. 5. Click to Translate 6. Sel Geometrical Set.1 as the to be translated element > It can not be selected. . Expected Result This operation should be correct. . Additional Information When selecting "Geometrical Set" in same part, this operation is OK. 1. Sel "Part.1" as current one 2. Sel Create a datum 3.Sel Translate 4.Sel Element :"Geometrical Set.1". (See Multi Output2 in tree:Line1,Extrude.1,Point3.) 5.Click OK > Multi Output2 disappears and Datum is displayed in Geometrical Set.1 .
Local fix
Problem summary
GSD : GEOMETRICAL SET CAN NOT BE SELECTED AS ELEMENT OF TRANSLA TE OPERATION WITH DATUM GSD : GEOMETRICAL SET CAN NOT BE SELECTED AS ELEMENT OF TRANSLATE OPERATION WITH DATUM . Scenario 1. Start CATIA V5R17SP2. 2. Open Product1.CATProduct 3. Change current to Part.2. (WorkBench: Generative Shape Design) 4. Click to Create Datum. 5. Click to Translate 6. Sel Geometrical Set.1 as the to be translated element > It can not be selected. . Expected Result This operation should be correct. . Additional Information When selecting "Geometrical Set" in same part, this operation is OK. 1. Sel "Part.1" as current one 2. Sel Create a datum 3.Sel Translate 4.Sel Element :"Geometrical Set.1". (See Multi Output2 in tree:Line1,Extrude.1,Point3.) 5.Click OK > Multi Output2 disappears and Datum is displayed in Geometrical Set.1 .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN CATIA DOCUMENTATION DELIVERED WITH CATIA VERSION 5 RELEASE 18. NOTE THAT DOCUMENTATION WILL ALSO BE INCLUDED IN V5R17 SP04. . In documentation : Shape Design and Styling Generative Shape Design Basics Tasks Using tools Selecting using Multi-Output . The following sentence has been added : You cannot select a geometrical set that belongs to another part as an input. You can only select a geometrical set belonging to the same part or a feature belonging to another part. .
Temporary fix
Comments
APAR Information
APAR number
HD60416
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-01-02
Closed date
2007-01-15
Last modified date
2007-01-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
15 January 2007