IBM Support

HD59787: MACHINING (PMPA) / GLOBAL FEATURE RECOGNITION : AXIS OF THE HOL E IS NOT RECOGNIZED CORRECTLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Machining (PMPA) / GLOBAL FEATURE
    RECOGNITION : AXIS OF THE HOLE IS NOT
    RECOGNIZED CORRECTLY
    .
    SCENARIO
    .
    1. Open CATProcess
    2. Run MPA Global feature recognition in
    Manufacturing. Select the body as Entity to
    recognize
    3. Set hole as feature enable tap holes and
    automatic merge
    4. Select the top surface as direction reference in
    the advanced tab page
    5. Check mark Create features only in this
    direction
    6. No pattern creation
    7. Run the recognition
    8. Note that 2 holes are recognized
    9. And there is only one hole in this direction that
    may be manufactured from this side of the part.
    The second hole has to be recognized from the
    other side of the part. See doc file for pictures.
    .
    PROBLEM
    .
    Global feature recognition does not recognize the
    hole correctly, the axis of one hole is not correct.
    .
    EXPECTED RESULT
    .
    Hole should be correctly recognized with Global
    feature recognition.
    .
    

Local fix

Problem summary

  • Machining (PMPA) / GLOBAL FEATURE RECOGNITION : AXIS OF THE HOL
    E IS NOT RECOGNIZED CORRECTLY
    Machining (PMPA) / GLOBAL FEATURE
    RECOGNITION : AXIS OF THE HOLE IS NOT
    RECOGNIZED CORRECTLY
    .
    SCENARIO
    .
    1. Open CATProcess
    2. Run MPA Global feature recognition in
    Manufacturing. Select the body as Entity to
    recognize
    3. Set hole as feature enable tap holes and
    automatic merge
    4. Select the top surface as direction reference in
    the advanced tab page
    5. Check mark Create features only in this
    direction
    6. No pattern creation
    7. Run the recognition
    8. Note that 2 holes are recognized
    9. And there is only one hole in this direction that
    may be manufactured from this side of the part.
    The second hole has to be recognized from the
    other side of the part. See doc file for pictures.
    .
    PROBLEM
    .
    Global feature recognition does not recognize the
    hole correctly, the axis of one hole is not correct.
    .
    EXPECTED RESULT
    .
    Hole should be correctly recognized with Global
    feature recognition.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD59787

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-12-05

  • Closed date

    2007-01-11

  • Last modified date

    2007-01-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 January 2007