APAR status
Closed as program error.
Error description
ASD : MEASURE INERTIA : UPDATE MARK IS DISPLAYED AFTER DOUBLE CLICK ON INERTIA VOLUME IN THE TREE . SCENARIO: SCENARIO: 1.Clear all of your CATSettings. 2.Start CATIA 3.Open the Sent CATProduct Workbench Assembly Design 4.Click Measure inertia icon 5.Select Product7 on the tree ---- Measure Inertia window is displayed 6.Activate the Keep measure 7.Click Create Geometry button ---- Geometry Creation window is displayed 8.Click OK button ---- Part3CATPart is created on a tree 9.Click Center of gravity ---- Measure Inertia window is displayed 10.Click OK button 11.Click Update all icon 12.Expand the Applications on the tree ---- The tree of Applications is opened 13.Expand the Measure on the tree ---- The tree of Measure is opened 14.Select InertiaVolume.1 on the tree by Click MB3 ---- Contextual menu is opened. 15.Select InertiaVolume.1 object - Measure Update by contextual menu 16.Expand the Part1 on the tree ---- The tree of Part1 is opened 17.Double click Part1 on the tree ---- It moves current to Part1 18.Double click Aluminum on the tree ---- Properties window is displayed 19.Click Analysis tab 20.Input 100kg_m3 as Density 21.Click OK button 22.Duble click Product7 on the tree ---- It moves current to Product7 23.Select InertiaVolume.1 on the tree by Click MB3 ---- Contextual menu is opened 24.Select InertiaVolume.1 object - Force Measure Update by the contextual menu 25.Click Update all icon ---- The position of the Point. 1 of Part3 moved with Update all of step 25 26.Double click InertiaVolume.1 on the tree ===== The updating mark is displayed. Even if Force Measure Update of the IneriaVolume is performed once again , the update mark does not disappear ==== This is a problem .
Local fix
Problem summary
ASD : MEASURE INERTIA : UPDATE MARK IS DISPLAYED AFTER DOUBLE C LICK ON INERTIA VOLUME IN THE TREE ASD : MEASURE INERTIA : UPDATE MARK IS DISPLAYED AFTER DOUBLE CLICK ON INERTIA VOLUME IN THE TREE . SCENARIO: SCENARIO: 1.Clear all of your CATSettings. 2.Start CATIA 3.Open the Sent CATProduct Workbench Assembly Design 4.Click Measure inertia icon 5.Select Product7 on the tree ---- Measure Inertia window is displayed 6.Activate the Keep measure 7.Click Create Geometry button ---- Geometry Creation window is displayed 8.Click OK button ---- Part3CATPart is created on a tree 9.Click Center of gravity ---- Measure Inertia window is displayed 10.Click OK button 11.Click Update all icon 12.Expand the Applications on the tree ---- The tree of Applications is opened 13.Expand the Measure on the tree ---- The tree of Measure is opened 14.Select InertiaVolume.1 on the tree by Click MB3 ---- Contextual menu is opened. 15.Select InertiaVolume.1 object - Measure Update by contextual menu 16.Expand the Part1 on the tree ---- The tree of Part1 is opened 17.Double click Part1 on the tree ---- It moves current to Part1 18.Double click Aluminum on the tree ---- Properties window is displayed 19.Click Analysis tab 20.Input 100kg_m3 as Density 21.Click OK button 22.Duble click Product7 on the tree ---- It moves current to Product7 23.Select InertiaVolume.1 on the tree by Click MB3 ---- Contextual menu is opened 24.Select InertiaVolume.1 object - Force Measure Update by the contextual menu 25.Click Update all icon ---- The position of the Point. 1 of Part3 moved with Update all of step 25 26.Double click InertiaVolume.1 on the tree ===== The updating mark is displayed. Even if Force Measure Update of the IneriaVolume is performed once again , the update mark does not disappear ==== This is a problem .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 18 GA level . Diagnosis ASD : MEASURE INERTIA : UPDATE MARK IS DISPLAYED AFTER DOUBLE CLICK ON INERTIA VOLUME IN THE TREE Update also fails . Correction Explanation Since the CATPart is created associatively, after the measure is created, so the measure is not aware of Product time stamp modification. The measuer comes to know only when it is duoble clicked or expanded. So unupdated icon appears when it is double clicked. This is because when the measure is double clicked, it verifies thetime stamp of the product, it has been chaged due to the inclution of the part. The real problem here was, it was not getting updated. Now this has been corrected and update is done correctly .
Temporary fix
Comments
APAR Information
APAR number
HD59684
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-11-30
Closed date
2007-03-22
Last modified date
2007-03-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R518 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
22 March 2007