APAR status
Closed as program error.
Error description
INTEROP LCA - CV5 (EHA) Linking backshell with connector in GBN black box leads to publications exposed at BB level . 1) In ENOVIA LCA create a new PRC. Add a component assembly node under the PRC and load it in CATIA V5. 2) In CATIA V5 create a new product under the opened component assembly node. 3) Define the new product as a GBN - workbench Equipment & Systems / Electrical Harness Discipline / Electrical Harness Assembly - Select "Geometrical Bundle" icon, indicate the new created product to define it as GBN. 4) Under the GBN node place a connector - Insert "Existing Component" and Select connector 5) Under the GBN node place a backshell - Insert "Existing Component" and Select backshell 6) In CATIA V5 Link the connector with the backshell - Change workbench to Equipment & Systems / Electrical Harness Discipline / Electrical Assembly Design - Select "Connect Electrical Devices" icon - Select connector and select backshell . At this stage the publication participating in the linking of the two components appear at the GBN level. This should not happen as the link is internal to the GBN black box. .
Local fix
Problem summary
INTEROP LCA - CV5 (EHA) Linking backshell with connector in GBN black box leads to publications exposed at BB level INTEROP LCA - CV5 (EHA) Linking backshell with connector in GBN black box leads to publications exposed at BB level . 1) In ENOVIA LCA create a new PRC. Add a component assembly node under the PRC and load it in CATIA V5. 2) In CATIA V5 create a new product under the opened component assembly node. 3) Define the new product as a GBN - workbench Equipment & Systems / Electrical Harness Discipline / Electrical Harness Assembly - Select "Geometrical Bundle" icon, indicate the new created product to define it as GBN. 4) Under the GBN node place a connector - Insert "Existing Component" and Select connector 5) Under the GBN node place a backshell - Insert "Existing Component" and Select backshell 6) In CATIA V5 Link the connector with the backshell - Change workbench to Equipment & Systems / Electrical Harness Discipline / Electrical Assembly Design - Select "Connect Electrical Devices" icon - Select connector and select backshell . At this stage the publication participating in the linking of the two components appear at the GBN level. This should not happen as the link is internal to the GBN black box. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 18 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP04 . Bad management of instance refercne level so leads to extra publications 517 .
Temporary fix
Comments
APAR Information
APAR number
HD59411
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-11-21
Closed date
2006-12-08
Last modified date
2007-02-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN SP51704
UP07/02/27 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: