APAR status
Closed as Permanent restriction.
Error description
PART : BROKEN LINK BETWEEN A CATPart AND A CATfct FILE AT THE OPENING . Scenario 1. Open CATIA 2. File/Open UPPER_CABINET.CATPart . Result : the Open action is done without trouble since SpdFunctionalStartups.CATfct is correctly in \intel_a\resources\graphic. . 3. File/Close 4. File/Open LOWER_CAB.CATPart . Result : The open is NOT done correctly (see in FunctionnalBody.1) and the following error message is displayed : "The startup catalog files in the following list could not be found or contain the wrong information for the active document. SpdFunctionalStartups.CATfct Verify your installation or ask the owner of this document to send them." . 5. File/open UPPER_CABINET.CATPart Result : It is ok .
Local fix
Problem summary
PART : BROKEN LINK BETWEEN A CATPart AND A CATfct FILE AT THE O PENING PART : BROKEN LINK BETWEEN A CATPart AND A CATfct FILE AT THE OPENING . Scenario 1. Open CATIA 2. File/Open UPPER_CABINET.CATPart . Result : the Open action is done without trouble since SpdFunctionalStartups.CATfct is correctly in \intel_a\resources\graphic. . 3. File/Close 4. File/Open LOWER_CAB.CATPart . Result : The open is NOT done correctly (see in FunctionnalBody.1) and the following error message is displayed : "The startup catalog files in the following list could not be found or contain the wrong information for the active document. SpdFunctionalStartups.CATfct Verify your installation or ask the owner of this document to send them." . 5. File/open UPPER_CABINET.CATPart Result : It is ok .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA . Incident Diagnosis The second part that is opened in session, either UPPER_CABINET.CATPart or LOWER_CAB.CATPart, cannot find the refered catalog SpdFunctionalStartups.CATfct. . Restriction Explanation The link to the CATfct is not exactly the same in both CATPart documents: UPPER_CABINET.CATPart refers to SPDFUNCTIONALSTARTUPS.CATfct, in capital letters, whereas LOWER_CAB.CATPart refers to SpdFunctionalStartups.CATfct, in small letters. The error occurs when loading the second CATPart in session, either UPPER_CABINET or LOWER_CAB, because the name of the pointed CATfct has been already put in cache memory, and is case-different. Actually, the file on disk has small letters. One may refer to a pointed document with a wrong case if the document is not a catalog. But concerning catalogs, the user is not allowed to change the case. . By-Pass UPPER_CABINET.CATPart should be rebuilt, with the right SpdFunctionalStartups.CATfct. .
Temporary fix
Comments
APAR Information
APAR number
HD59153
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
515
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-11-14
Closed date
2007-02-02
Last modified date
2007-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 February 2007