APAR status
Closed as documentation error.
Error description
LacMac : Incorrect tool path on profile turning operation for some angle values. . SCENARIO: 1) Open the provided CATProcess 2) Replay tool path RESULT: The tool path is correct 3) Edit the tool path and modify the angle value 97 to 98 in 'Strategy/Machining' for Lift off angle 4) Compute the toolpath 5) Replay the tool path PROBLEM: The tool path is incorrect .
Local fix
Problem summary
LacMac : Incorrect tool path on profile turning operation for s ome angle values LacMac : Incorrect tool path on profile turning operation for some angle values. . SCENARIO: 1) Open the provided CATProcess 2) Replay tool path RESULT: The tool path is correct 3) Edit the tool path and modify the angle value 97 to 98 in 'Strategy/Machining' for Lift off angle 4) Compute the toolpath 5) Replay the tool path PROBLEM: The tool path is incorrect .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN CATIA DOCUMENTATION DELIVERED WITH CATIA VERSION 5 RELEASE 18. NOTE THAT DOCUMENTATION WILL ALSO BE INCLUDED IN V5R17SP04. . Documentation Reference Lathe Machining Reference Profile Finish Turning Operations . MODIFICATION: Note that the lead-in angle is defined with respect to the normal to the cutting direction. Range of lead-in angle is from -90 degree to 135 degree for all the tools except for Grooving tool, where it ranges from 0 degree to 90 degree. . Note that the lift-off angle is defined with respect to the normal to the cutting direction. Range of lead-in angle is from -90 degree to 135 degree for all the tools except for Grooving tool, where it ranges from 0 degree to 90 degree. . For groove inserts, range of lead-in and lift-off has always been 0 to 90 degrees. This can be tested by using Groove inserts in a Grooving operation, where there is an explicit error message, in case these angles are set > 90. There are a number of ways to obtain the correct tool path. a) Use a Grooving operation with Groove inserts as mentioned above b) Any other operations with Groove inserts should also follow the above rule c) Use of Profile Finishing with other inserts .
Temporary fix
Comments
APAR Information
APAR number
HD58456
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-10-26
Closed date
2006-11-30
Last modified date
2006-11-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
30 November 2006