APAR status
Closed as documentation error.
Error description
STANDARD LINETYPE AND THICKNESS ARE NOT APPLIED ON GRAPHICS PROPERTIES OF CENTER LINE . Preparation: Standard values of Line type and Thickness of Center Line are changed from default graphic properties to 8 and 4 respectively in the ANSI.xml file Scenario: 1. Open a New CATDrawing file with the prepared Standard. 2. Create a Circle. 3. Create a Center Line on the Circle. 4. Show the graphic properties after right click on the Center Line. Problem!! The values of Line type and Thickness are not the updated standard value but the default value. Expected Result: The updated Standard Line type and Thickness should be applied on Graphic Properties of Center Line. .
Local fix
Problem summary
STANDARD LINETYPE AND THICKNESS ARE NOT APPLIED ON GRAPHICS PRO PERTIES OF CENTER LINE STANDARD LINETYPE AND THICKNESS ARE NOT APPLIED ON GRAPHICS PROPERTIES OF CENTER LINE . Preparation: Standard values of Line type and Thickness of Center Line are changed from default graphic properties to 8 and 4 respectively in the ANSI.xml file Scenario: 1. Open a New CATDrawing file with the prepared Standard. 2. Create a Circle. 3. Create a Center Line on the Circle. 4. Show the graphic properties after right click on the Center Line. Problem!! The values of Line type and Thickness are not the updated standard value but the default value. Expected Result: The updated Standard Line type and Thickness should be applied on Graphic Properties of Center Line. .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN CATIA DOCUMENTATION DELIVERED WITH CATIA VERSION 5 RELEASE 18. . Documentation Reference Interactive Drafting User Guide Administration Tasks Setting Standard Parameters Line Type Definition MODIFICATION: New text added to an "Important" section: Information : From V5 R17, it is possible to assign bi-dimensional line types on all mono-parametric geometries (line, circle, spline). However, the line type 8 is an exception: it is taken into account on geometrical lines and circles. Note that you can select and apply line type 8 to any other element, however your change will not be taken into account .
Temporary fix
Comments
APAR Information
APAR number
HD57822
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-10-10
Closed date
2006-11-03
Last modified date
2006-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: