IBM Support

HD57739: LMG / ROUGH GROOVING / CHANGE OUTPUT POINT OPTION LEADS TO COLL ISION WHEN SWITCH FROM P9 TO P9R

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • LMG / ROUGH GROOVING / CHANGE OUTPUT
    POINT OPTION LEADS TO COLLISION WHEN
    SWITCH FROM P9 TO P9R
    .
    Scenario:
    When performing a Rough Grooving operation, we
    used the Change Output Point option in the options
    and strategy tab. When processing the program,
    we found that the offset switch was occuring at the
    wrong place and would create a collision
    while retracting.
    .
    1.Open the attached CATPROCESS
    2.Review the toolpath of the existing MO.
    3.Refer the apt file and the ppt sent.
    .
    The tool has switch to P9 while retracting from
    LIFTOFF position. This will create an offset change
    while the tool is inside part to a position where a
    collision will occurs.The offset switch should occur
    only when the tool is fully retracted from part
    .
    See attached ppt document and APT file
    .
    

Local fix

Problem summary

  • LMG / ROUGH GROOVING / CHANGE OUTPUT POINT OPTION LEADS TO COLL
    ISION WHEN SWITCH FROM P9 TO P9R
    LMG / ROUGH GROOVING / CHANGE OUTPUT
    POINT OPTION LEADS TO COLLISION WHEN
    SWITCH FROM P9 TO P9R
    .
    Scenario:
    When performing a Rough Grooving operation, we
    used the Change Output Point option in the options
    and strategy tab. When processing the program,
    we found that the offset switch was occuring at the
    wrong place and would create a collision
    while retracting.
    .
    1.Open the attached CATPROCESS
    2.Review the toolpath of the existing MO.
    3.Refer the apt file and the ppt sent.
    .
    The tool has switch to P9 while retracting from
    LIFTOFF position. This will create an offset change
    while the tool is inside part to a position where a
    collision will occurs.The offset switch should occur
    only when the tool is fully retracted from part
    .
    See attached ppt document and APT file
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R17SP03 AND ON V5R16SP08.
    .
    Incident Diagnosis
    LMG / ROUGH GROOVING / CHANGE OUTPUT
    POINT OPTION LEADS TO COLLISION WHEN
    SWITCH FROM P9 TO P9R
    Correction Explanation
    Tool compensation point was not properly
    addressed in retract motion for lathe.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD57739

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-10-09

  • Closed date

    2006-10-27

  • Last modified date

    2006-11-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R516 PSN SP51608

       UP06/11/27 I 1000

  • R517 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: