Error description
CATScripts do not work any more with xlC.rte 8.0.0.5 and xlsmp.rte 1.6.0.0 (= U808794) . we have a serious problem with our CATIA V5 installation at our server. We installed the prereqs for AIX 5.3 C++ runtime version 8. Now our CATSCRIPT macros are no longer running. . Scenario: 1. install AIX 5.3ML4 and install "xlC.rte 8.0.0.5 + xlsmp.rte 1.6.0.0" 2. start CATIA V5R15SP4 4. Open new CATPart 3. run macro "PMR_31369.CATScript" We get the following error message: ScriptingERR_1004 "Execute the script "PMR_31369.CATScript". The CATScript scripting engine in not properly installed. Install the scripting engine and run your script again." .
Local fix
Problem summary
CATScripts do not work any more with xlC rte 8 0 0 5 and xlsmp rte 1 6 0 0 (= U808794) CATScripts do not work any more with xlC.rte 8.0.0.5 and xlsmp.rte 1.6.0.0 (= U808794) . we have a serious problem with our CATIA V5 installation at our server. We installed the prereqs for AIX 5.3 C++ runtime version 8. Now our CATSCRIPT macros are no longer running. . Scenario: 1. install AIX 5.3ML4 and install "xlC.rte 8.0.0.5 + xlsmp.rte 1.6.0.0" 2. start CATIA V5R15SP4 4. Open new CATPart 3. run macro "PMR_31369.CATScript" We get the following error message: ScriptingERR_1004 "Execute the script "PMR_31369.CATScript". The CATScript scripting engine in not properly installed. Install the scripting engine and run your script again." .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 18 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP02 and ON V5R16SP08. . .Incident Diagnosis CATScripts do not work any more with xlC rte 8 0 0 5 and xlsmp rte 1 6 0 0 (= U808794) . .Correction Explanation This xlC level changes the order in which the static object are loaded, which lead to a problem in the Mainwin init . .Answer and By-Pass None. .
Temporary fix
Comments
APAR Information
APAR number
HD57004
Reported component name
CATIA V5 AIX
Reported component ID
569101000
Reported release
515
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-09-14
Closed date
2006-11-16
Last modified date
2006-11-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 AIX
Fixed component ID
569101000
Applicable component levels
R515 PSN
UP
R516 PSN SP51608
UP06/11/27 I 1000
R517 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
27 November 2006