APAR status
Closed as suggestion for future release.
Error description
FTA / DIAMETER SYMBOL CAN NOT BE ADDED TO ANGULARITY TOLERANCE . Scenario: 1.Open attached Angularity_example01.CATPart. 2.WB FTA 3.Selct diameter dimension of middle hole and try to create angle tolerance with DRF AB. 4. Tolerance frame does not show diameter symbol. 5. Refer attached standards showing diameter symbol with angularity tolerance. . Expected behavior. Diameter symbol should be provided in above case . .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT WHICH CANNOT BE INCORPORATED IN VERSION 5R18 PLEASE CONTACT YOUR SUPPORT DEPARTMENT IN ORDER TO OPEN A REQUIREMENT FORM. . Incident Diagnosis: The angularity tolerance applied to the axis is governed by a single angle parameter. The angularity tolerance specifies the allowed variations of this single angle parameter. With current available infrastructure CATIA consider angular variation only in plane. In order to apply diameter symbol with angularity tolerance, the current infrastructure has to be modified. . Development Justification: In order to consider the cylindrical tolerance zone, FTA data model and Angularity tolerance edition panel need to be change. In order to support ASME standard possibility, the required modification is huge and not feasible to manage through APAR channel. This will require complete rethinking/redesign of existing functionalities. Such task is possible through development channel.Henec required modification is considered as suggestion for development in future. . Bypass: If possible, we advise you to use straight ness specification in order to define the cylindrical tolerance zone. 1- Create an angularity tolerance without diameter symbol (tolerance zone being 2 // planes) 2- Create an axis straightness tolerance . .
APAR Information
APAR number
HD56941
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-09-13
Closed date
2006-09-29
Last modified date
2006-09-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
29 September 2006