APAR status
Closed as program error.
Error description
ITEV5CV5 / ENOVIA CONNECTION IS LOST ON USING REUSE PATTERN IN ASSEMBLY SCENARIO: 1. Start CATIA V5 and Enovia LCA 2. In LCA, Open the Part editor and search for the Product test-01 3. Send the Product to CATIA V5 4. In CATIA, enter the Assembly design Workbench 5. Expand the Specification tree 6. Select the Circular Pattern in the Part 7. Using CTRL key select the Part 8. Click on the Reuse Pattern command 9. Check the two options 10. Click OK to create the Assembly Pattern is created. 11. Save the Product to LCA 12. Edit any of the offset constraints. Ex. Change the value of Offset.5 to 5mm. 13. Save the product again to LCA 14 Now Repeat steps 6 to 10 to create another Assembly Pattern using the Rectangular Pattern and the Part 15. Another Assembly pattern is created. 16. Save the product to LCA and close it in CATIA. 17. In LCA, Select the product from the part editor and send it to CATIA V5. . OBSERVATION: An Error occurs ᄄ You have lost connection with the ENOVIA Server. Click OK to exit. On CATIA side too you get the same Error message saying that the ENOVIA LCA connection was lost while saving. . EXPECTED RESULT: The Connection should not be lost on saving and the Product should be successfully saved in LCA and loaded in CATIA. . .
Local fix
Problem summary
ITEV5CV5 / ENOVIA CONNECTION IS LOST ON USING REUSE PATTERN IN ASSEMBLY ITEV5CV5 / ENOVIA CONNECTION IS LOST ON USING REUSE PATTERN IN ASSEMBLY SCENARIO: 1. Start CATIA V5 and Enovia LCA 2. In LCA, Open the Part editor and search for the Product test-01 3. Send the Product to CATIA V5 4. In CATIA, enter the Assembly design Workbench 5. Expand the Specification tree 6. Select the Circular Pattern in the Part 7. Using CTRL key select the Part 8. Click on the Reuse Pattern command 9. Check the two options 10. Click OK to create the Assembly Pattern is created. 11. Save the Product to LCA 12. Edit any of the offset constraints. Ex. Change the value of Offset.5 to 5mm. 13. Save the product again to LCA 14 Now Repeat steps 6 to 10 to create another Assembly Pattern using the Rectangular Pattern and the Part 15. Another Assembly pattern is created. 16. Save the product to LCA and close it in CATIA. 17. In LCA, Select the product from the part editor and send it to CATIA V5. . OBSERVATION: An Error occurs You have lost connection with the ENOVIA Server. Click OK to exit. On CATIA side too you get the same Error message saying that the ENOVIA LCA connection was lost while saving. . EXPECTED RESULT: The Connection should not be lost on saving and the Product should be successfully saved in LCA and loaded in CATIA. . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON ENOVIA VERSION 5 RELEASE 18 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP01 AND ON V5R16SP07. .
Temporary fix
Comments
APAR Information
APAR number
HD54322
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-06-30
Closed date
2006-07-27
Last modified date
2006-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R516 PSN SP51607
UP06/10/03 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 October 2006