APAR status
Closed as unreproducible in next release.
Error description
Scenario: 1- File / Open CATProduct 2- In 3D area select BNS called "ghostBNS" and localize MultiBNS identification into specification tree; Expand identified multiBNS 3- By selecting one by one highlight these 7 branchables in the 3D area The Ghost BNS is never highlighted by selecting branchable from specification tree 4- Create a new Catproduct 5- Switch to EHF workbench 6- Into the new CATproduct Defined EHF parameter Mandatory : Coarse /Regular Minimun Angle : What ever the value (90 deg) 7- Extract Electrical data from M87S315151000E1.CATProduct to 3D flattening Catproduct within EHF extraction function Select the icon then GBN Warning appear click OK 8- Electrical GBN have been extracted to 3D flattening CATproduct; an update is required 9- Update all 10- Flatten Electrical data of 3D flattening Catproduct within EHF Flattening function Select icon Remaining EHF parameters dialog box appear but can not be validate (OK button is frozen) 11- Select In 3D geometry this BNS 12- Click on select all branches button 13- All Electrical network is selected except left one (normal cause no electrical connection between twice network) 14- Click on OK 15- Repeat action from 1 to 10 16- Select In 3D geometry this BNS Impossible to select It 17- Select In 3D geometry this BNS BNS can be selected 18- Click on select all branches button 20- More than the Left electrical network is selected (normally impossible cause no electrical links between them) 21- Commit flattening operation Result: Error message : Electrical software error inside the flatten command .
Local fix
Problem summary
EHF - BNS links to electrical network but not referenced into specification tree Scenario: 1- File / Open CATProduct 2- In 3D area select BNS called "ghostBNS" and localize MultiBNS identification into specification tree; Expand identified multiBNS 3- By selecting one by one highlight these 7 branchables in the 3D area The Ghost BNS is never highlighted by selecting branchable from specification tree 4- Create a new Catproduct 5- Switch to EHF workbench 6- Into the new CATproduct Defined EHF parameter Mandatory : Coarse /Regular Minimun Angle : What ever the value (90 deg) 7- Extract Electrical data from M87S315151000E1.CATProduct to 3D flattening Catproduct within EHF extraction function Select the icon then GBN Warning appear click OK 8- Electrical GBN have been extracted to 3D flattening CATproduct; an update is required 9- Update all 10- Flatten Electrical data of 3D flattening Catproduct within EHF Flattening function Select icon Remaining EHF parameters dialog box appear but can not be validate (OK button is frozen) 11- Select In 3D geometry this BNS 12- Click on select all branches button 13- All Electrical network is selected except left one (normal cause no electrical connection between twice network) 14- Click on OK 15- Repeat action from 1 to 10 16- Select In 3D geometry this BNS Impossible to select It 17- Select In 3D geometry this BNS BNS can be selected 18- Click on select all branches button 20- More than the Left electrical network is selected (normally impossible cause no electrical links between them) 21- Commit flattening operation Result: Error message : Electrical software error inside the flatten command .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 16. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 18 GA level AND ON V5R16SP06 NOTE THAT THIS PROBLEM IS ALSO UNREPRODUCIBLE ON V5R17GA. Incident Diagnosis The harness has a ghost Bundle Segment which does not have a branchable. This incorrect data was identified by Flatten command and so the command stopped. Answer and By-Pass This problem has been corrected on V5R16 SP6 and V5R17ga by an internal Incident Report. .
APAR Information
APAR number
HD54063
Reported component name
CATIA V5 HP-UX
Reported component ID
569102000
Reported release
516
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-06-20
Closed date
2006-06-27
Last modified date
2006-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 HP-UX
Fixed component ID
569102000
Applicable component levels
R516 PSN SP51606
UP06/08/01 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 August 2006