APAR status
Closed as program error.
Error description
PRINT / LINE AND EDGE WIDTH NOT IN CONFIRMITY WITH STANDARD WHEN VDCType = INTEGER PARAMETER FOR CGM. . SCENARIO: 1. Open CATIA 2. Go to tools / option /compatibility / Graphics Format 3. Choose CGM and Click on configuration 4. Select the parameters as shown in the image sent with the DOC 5. Click on Printer setup and select 3Dplm printer to be added 6. In driver select CGM (Computer Graphics Metafile) 7. Click on advanced TAB, and select again the parameters as shown in the DOC (2nd time) 8. Click on File /print and choose the printer just added. 9. In the print to file select a path and the file name with extension CGM. 10. Open the CGM in Metacheck and extract the report. . OBSERVATION: When we create a CGM file with VDCType = INTEGER parameter, errors appears on LINE WIDTH and EDGE WIDTH. These errors are not in conformity with the standard CGM ISO 8632-3 . EXPECTED RESULT: The line width and the edge with should be according to the standard CGM ISO 8632-3 . .
Local fix
Problem summary
PRINT / LINE AND EDGE WIDTH NOT IN CONFIRMITY WITH STANDARD WHE N VDCType = INTEGER PARAMETER FOR CGM PRINT / LINE AND EDGE WIDTH NOT IN CONFIRMITY WITH STANDARD WHEN VDCType = INTEGER PARAMETER FOR CGM. . SCENARIO: 1. Open CATIA 2. Go to tools / option /compatibility / Graphics Format 3. Choose CGM and Click on configuration 4. Select the parameters as shown in the image sent with the DOC 5. Click on Printer setup and select 3Dplm printer to be added 6. In driver select CGM (Computer Graphics Metafile) 7. Click on advanced TAB, and select again the parameters as shown in the DOC (2nd time) 8. Click on File /print and choose the printer just added. 9. In the print to file select a path and the file name with extension CGM. 10. Open the CGM in Metacheck and extract the report. . OBSERVATION: When we create a CGM file with VDCType = INTEGER parameter, errors appears on LINE WIDTH and EDGE WIDTH. These errors are not in conformity with the standard CGM ISO 8632-3 . EXPECTED RESULT: The line width and the edge with should be according to the standard CGM ISO 8632-3 . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 18 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP01 AND ON V5R16SP06. . Incident Diagnosis PRINT / LINE AND EDGE WIDTH NOT IN CONFIRMITY WITH STANDARD WHEN VDCType = INTEGER PARAMETER FOR CGM . Correction Explanation Correction about the edge width and line width specification mode not taking account inside the edge width and line width entities is done. . Answer and By-Pass . .
Temporary fix
Comments
APAR Information
APAR number
HD53976
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
515
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-06-16
Closed date
2006-07-06
Last modified date
2006-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R515 PSN
UP
R516 PSN SP51606
UP06/08/01 I 1000