APAR status
Closed as user error.
Error description
SAVE TO ENOVIA FAILS WHEN TECH PACKAGE AUTOMATICALLY ADDED TO CATIA SESSION. . User is creating Wire bundle as in PMR 09856,411,000 but this user cannot save to ENOVIA at all. He is getting two error messages: Error An error occurred during save sequence. Save aborted. Error Failure when creating the TechPack Technological Package.1 in database. This user has A-Designer role. Another user who has Designer role can save. Results: A-Designer role is unable to save after the Tech package is added Expected results: The A-Designer role should be able to save even with the Tech Package in session. Please see attached file for screen shots, server trace and PnO export. .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
Incident Diagnosis SAVE TO ENOVIA FAILS WHEN TECH PACKAGE AUTOMATICALLY ADDED TO CATIA SESSION . Correct Application Problem occurs when trying to lock the TP being created. This is due to P&O data-groups defined with a customized attribute 'BOECACECCNumber' which is recognized by P&O. Moreover these data-goups are attached to various processes which all causes the associated operations to fail. Example, DocumentRevision.ViewFileContents and VPMObject.Lock. Example of errors one may see in the traces: VpmObjectLock : CATVpmObjectLock::PutLock() { ... VpmSCManager : : : : : GetGranteeCondition() { VpmSCManager : : : : : : -> Process already in cache at 4 - Retrieving predicate VpmSCManager : : : : : : ==> Final condition: NOT(oneof BOECACECCNumber in 1E001 1E101 1E103 1E201 1E202 2E001 2E002 2E003 2E101 2E201 7E004 9E003 ITAR ) and V_organization eq LABINAL or V_organization = $cur_org and NOT(V_status = Approved) VpmSCManager : : : : : } VpmSCManager : : : : : === Testing eXtended DataGroup condition === VpmInfo : : : : : CATVpmInfo::Push() { VpmInfo : : : : : : *********************************** ******* ************************ VpmInfo : : : : : : Push( 2): 'BOECACECCNumber' is not a valid attribute . Documentation Reference CATIA / ENOVIA Interoperability Getting Started Save .
APAR Information
APAR number
HD50446
Reported component name
ENOVIA LCA NT>X
Reported component ID
569151700
Reported release
516
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-03-06
Closed date
2006-03-21
Last modified date
2006-07-12
APAR is sysrouted FROM one or more of the following: