Error description
COMPOSITE DESIGN / GENERATING EXPLODED PLIES WITH CUT-PIECE DUPLICATES THE EXPLODED PLIES. . SCENARIO: 1.) Open CATPart in Composite Design workbench 2.) Activate the composite design workbench 3.) Create exploded plies for plies group.1 3a.) Insert => Plies => ply exploder 3b.) Select shell constant offset option 3c.) Set scale to 10 4.) Regenerate exploded plies for plies group.1 with new options 4a.) Insert => Plies => ply exploder 4b.) Select draped tessellated surface option 4c.) Set scale to 20 NOTE: old exploded surfaces are replaced with the new ones. 5.) Generate exploded plies for Cut-Pieces 5a.) Insert => Plies => ply exploder 5b.) Select 'take cut pieces into account' 5c.) Select shell constant offset option 5d.) Set scale to 10 . OBSERVATION: Additional exploded surface geometry is created. This can cause problems in viewing the cross- sections generated in DMU. The exploded plies for the plies and cut-pieces cannot be managed independently with the contextual menus. Therefore, the contextual 'hide/show' and 'delete' exploded surface options are all or nothing. The user must delete all the exploded plies and recreate. Alternatively, manually delete the unwanted exploded surfaces. . EXPECTED RESULT: Previously generated exploded plies are replaced with the new exploded surfaces representing the cut-piece geometry. Ideally, user would be warned that exploded geometry exists for the plies and given the option to delete and continue, keep and continue, or cancel the operation. This is also true if the cut-piece exploded plies are generated first and then the exploded plies are generated for the plies. . .
Local fix
Problem summary
COMPOSITE DESIGN / GENERATING EXPLODED PLIES WITH CUT-PIECE DUP LICATES THE EXPLODED PLIES. COMPOSITE DESIGN / GENERATING EXPLODED PLIES WITH CUT-PIECE DUPLICATES THE EXPLODED PLIES. . SCENARIO: 1.) Open CATPart in Composite Design workbench 2.) Activate the composite design workbench 3.) Create exploded plies for plies group.1 3a.) Insert => Plies => ply exploder 3b.) Select shell constant offset option 3c.) Set scale to 10 4.) Regenerate exploded plies for plies group.1 with new options 4a.) Insert => Plies => ply exploder 4b.) Select draped tessellated surface option 4c.) Set scale to 20 NOTE: old exploded surfaces are replaced with the new ones. 5.) Generate exploded plies for Cut-Pieces 5a.) Insert => Plies => ply exploder 5b.) Select 'take cut pieces into account' 5c.) Select shell constant offset option 5d.) Set scale to 10 . OBSERVATION: Additional exploded surface geometry is created. This can cause problems in viewing the cross- sections generated in DMU. The exploded plies for the plies and cut-pieces cannot be managed independently with the contextual menus. Therefore, the contextual 'hide/show' and 'delete' exploded surface options are all or nothing. The user must delete all the exploded plies and recreate. Alternatively, manually delete the unwanted exploded surfaces. . EXPECTED RESULT: Previously generated exploded plies are replaced with the new exploded surfaces representing the cut-piece geometry. Ideally, user would be warned that exploded geometry exists for the plies and given the option to delete and continue, keep and continue, or cancel the operation. This is also true if the cut-piece exploded plies are generated first and then the exploded plies are generated for the plies. . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 17 GA level. . Incident Diagnosis GENERATING EXPLODED PLIES WITH CUT-PIECE DUPLICATES THE EXPLODED PLIES. . Correction Explanation The code changes have been made to check for exploded plies under both ply and cut-piece before creating a new exploded plies. . Answer and By-Pass NONE . .
Temporary fix
Comments
APAR Information
APAR number
HD49571
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-02-14
Closed date
2006-03-14
Last modified date
2006-03-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
14 March 2006