APAR status
Closed as program error.
Error description
After add a command to a toolbar CATIA crashes after restart if no default document are opened. Scenario 1. Start CATIA 2. Select Tools / Options / General / User Interface Style / P2. (Figure1) 3. Select Tools / Options / Infrastructure / Product Structure Tab Part Number / Manual input ON. (Figure2) 4. Close CATIA. 5. Start CATIA 6. Select Start / Shape / Automotive BIW Fastening. 7. Select Tools / Customize / Command Tab. 8. The Measure Inertia command is added to Measure Toolbar. (Figure3) 9)Click Close. 10)Close CATIA. 11)Start CATIA. 12)Click Cancel.(Figure4) 13)Select Start / Mechanical Design ->Part Design Workbench. 14)Select Start / Mechanical Design ->Assembly Design Workbench. Result) Command interrupted. It described it as an example by "Measure Inertia" command this time. It "Click OK to terminate" even if an arbitrary command is added according to the above-mentioned procedure. .
Local fix
Problem summary
After add a command to a toolbar CATIA crashes after restart if no default document are opened. After add a command to a toolbar CATIA crashes after restart if no default document are opened. Scenario 1. Start CATIA 2. Select Tools / Options / General / User Interface Style / P2. (Figure1) 3. Select Tools / Options / Infrastructure / Product Structure Tab Part Number / Manual input ON. (Figure2) 4. Close CATIA. 5. Start CATIA 6. Select Start / Shape / Automotive BIW Fastening. 7. Select Tools / Customize / Command Tab. 8. The Measure Inertia command is added to Measure Toolbar. (Figure3) 9)Click Close. 10)Close CATIA. 11)Start CATIA. 12)Click Cancel.(Figure4) 13)Select Start / Mechanical Design ->Part Design Workbench. 14)Select Start / Mechanical Design ->Assembly Design Workbench. Result) Command interrupted. It described it as an example by "Measure Inertia" command this time. It "Click OK to terminate" even if an arbitrary command is added according to the above-mentioned procedure. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 17 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R16SP03. The abend was the result of a bad type returned by a pointer cast in the code. The problem is fixed: The crash does no more occur. .
Temporary fix
Comments
APAR Information
APAR number
HD48920
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-01-24
Closed date
2006-02-14
Last modified date
2006-03-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R516 PSN SP51603
UP06/03/06 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 March 2006