IBM Support

HD47402: GSA : WHEN REPLACE IS DONE, THICKNESS IS NOT REFLECTED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • GSA : When replace is done, thickness is not
    reflected.
    .
    SCENARIO:
    1. Open the provided CATAnalysis
    2. Double click on 2D property
    RESULT:
    Thickness is equal to 1mm (formula)
    3. Select Edit/Links
    4. Replace Part2.CATPart by Part5.CATPart
    5. Click OK
    6. Double Click on 2D property
    PROBLEM:
    Thickness is still equal to 1mm (without formula)
    whereas Part Thickness is 1.5mm
    .
    

Local fix

Problem summary

  • GSA : When replace is done, thickness is not reflected
    GSA : When replace is done, thickness is not
    reflected.
    .
    SCENARIO:
    1. Open the provided CATAnalysis
    2. Double click on 2D property
    RESULT:
    Thickness is equal to 1mm (formula)
    3. Select Edit/Links
    4. Replace Part2.CATPart by Part5.CATPart
    5. Click OK
    6. Double Click on 2D property
    PROBLEM:
    Thickness is still equal to 1mm (without formula)
    whereas Part Thickness is 1.5mm
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA.
    .
    Incident Diagnosis
    When the support for a 2D property is changed
    (part replaced using edit links), then the thickness
    which was earlier valuated by a formula (using
    parameters from the earlier part) is no more
    valuated by any formula. Instead the thickness
    reflected is taken from settings.
    .
    Restriction Explanation
    The formula valuating the thickness cannot relink
    automaticaly to parameters in the new part after
    replace. This is standard CATIA behavior. Also
    there is no publication mechanism involved here.
    .
    By-Pass
    The previous relation for the thickness is not lost
    but deactivated. Using contextual menu on the
    relation, user can edit the formula and modify the
    input parameter to the appropriate parameter in
    the new part manually. This relation can be
    activated to valuate the thickness.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD47402

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    514

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2005-12-06

  • Closed date

    2005-12-14

  • Last modified date

    2005-12-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
14 December 2005