Error description
GSD / 'JOIN' CAN NOT CREATED IF ALL THE SURFACES ARE SELECTED TOGETHER . SCENARIO: 0) Start CATIA V5R16GA. 1) Open the attached CATPart'. Workbench : 'GSD'. 2) Click 'Join' icon. => 'Join Definition' panel is displayed. 3) Select 'Surface1' - 'Surface5' as 'Element to join'. 4) Uncheck 'Check connexity'. 5) Click 'OK'. =>'Update Error' panel is displayed. =>'Tangency Error' is displayed on 'Suface4' and 'Surface5' in Geometry Area. 6) Click 'OK' in 'Update Error' panel. => 'Join Definition' panel is displayed,again. 7) Click 'Remove Mode'. 8) Select one Surface from Geometry Area.< (Any surface is ok.) This case select 'Surface.1'. =>'Surface.2' - 'Surface.5' are selected as Elements to Join. 9) Click 'OK'. =>'Join.1' is created.<. < RESULT > -'Join' cannot be created with 'Tangency Error', if all 'Surface' are selected. -'Join' can be created even if it deletes surface which is unrelated to a 'Tangency Error'. . < RESULT TO EXPECT > 'Join' should be created if all 'Surface' are selected. . < Remarks > -If expansion 'Surface.4' and 'Surface.5',It seems to cross. 'Join' can be created if 'Surface.4' and 'Surface.5' are selected. .
Local fix
Problem summary
GSD / 'JOIN' CAN NOT CREATED IF ALL THE SURFACES ARE SELECTED T OGETHER GSD / 'JOIN' CAN NOT CREATED IF ALL THE SURFACES ARE SELECTED TOGETHER . SCENARIO: 0) Start CATIA V5R16GA. 1) Open the attached CATPart'. Workbench : 'GSD'. 2) Click 'Join' icon. => 'Join Definition' panel is displayed. 3) Select 'Surface1' - 'Surface5' as 'Element to join'. 4) Uncheck 'Check connexity'. 5) Click 'OK'. =>'Update Error' panel is displayed. =>'Tangency Error' is displayed on 'Suface4' and 'Surface5' in Geometry Area. 6) Click 'OK' in 'Update Error' panel. => 'Join Definition' panel is displayed,again. 7) Click 'Remove Mode'. 8) Select one Surface from Geometry Area.< (Any surface is ok.) This case select 'Surface.1'. =>'Surface.2' - 'Surface.5' are selected as Elements to Join. 9) Click 'OK'. =>'Join.1' is created.<. < RESULT > -'Join' cannot be created with 'Tangency Error', if all 'Surface' are selected. -'Join' can be created even if it deletes surface which is unrelated to a 'Tangency Error'. . < RESULT TO EXPECT > 'Join' should be created if all 'Surface' are selected. . < Remarks > -If expansion 'Surface.4' and 'Surface.5',It seems to cross. 'Join' can be created if 'Surface.4' and 'Surface.5' are selected. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 17 GA level. . Incident Diagnosis The error message of the Join is not clear enough. . Correction Explanation A new error message has been delivered to help the user to understand the problem. The new message is : Join operator: Some edges haven't been merged, although they are closer than resolution, because skin will be unorientable. They may come from faces overlap. Modify adjacent faces in order to suppress these overlaps. .
Temporary fix
Comments
APAR Information
APAR number
HD46727
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-11-17
Closed date
2005-11-29
Last modified date
2005-11-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN
UP