IBM Support

HD44649: PART DESIGN / CHANGING THE NAME OF PUBLICATION RESULTS IN LINK LOSS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • PART DESIGN / CHANGING THE NAME OF
    PUBLICATION RESULTS IN LINK LOSS
    .
    From CATIA V5, create 2 CATParts
    -In CATPart1, create any solid
    -On solid part body, MB3+ Properties and change
    the name of the body to "test"
    -Go to Tools+Publication and select body "test"
    for publishing.
    -Save CATPart1
    -MB3+Copy body "test"
    -In CATPart2, MB3+Paste Special+As result with
    link. This should result in a body called "Result
    of test"
    -Save CATPart2
    -Close CATPart2
    -In CATPart1, go to Tools+Publish
    -From publication list, rename the publication by
    double clicking in the name field and typing new
    name. Rename from "test" to "solid"
    -Save CATPart1
    -Reopen CATPart2
    -In CATPart2 go to Edit+Links
    -Notice in the links panel the status now
    reads "reference not found". There is now no way
    to repoint or reconnect the copied solid back to
    the new publish name.
    .
    

Local fix

Problem summary

  • PART DESIGN / CHANGING THE NAME OF PUBLICATION RESULTS IN LINK
    LOSS
    PART DESIGN / CHANGING THE NAME OF
    PUBLICATION RESULTS IN LINK LOSS
    .
    From CATIA V5, create 2 CATParts
    -In CATPart1, create any solid
    -On solid part body, MB3+ Properties and change
    the name of the body to "test"
    -Go to Tools+Publication and select body "test"
    for publishing.
    -Save CATPart1
    -MB3+Copy body "test"
    -In CATPart2, MB3+Paste Special+As result with
    link. This should result in a body called "Result
    of test"
    -Save CATPart2
    -Close CATPart2
    -In CATPart1, go to Tools+Publish
    -From publication list, rename the publication by
    double clicking in the name field and typing new
    name. Rename from "test" to "solid"
    -Save CATPart1
    -Reopen CATPart2
    -In CATPart2 go to Edit+Links
    -Notice in the links panel the status now
    reads "reference not found". There is now no way
    to repoint or reconnect the copied solid back to
    the new publish name.
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    CATIA VERSION 5 RELEASE 14.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    CATIA VERSION 5 RELEASE 17 GA level
    .
    ADDITIONAL INFORMATION:
    .
    The problem is also not reproduced at V5R16 GA.
    .
    An option of CHANGE PUBLICATION is provided in
    the EDIT/LINKS panel which allows to change the
    publication in such cases.
    GO to Edit/Links Panel after the scenario and then
    change the Publication.
    .
    

APAR Information

  • APAR number

    HD44649

  • Reported component name

    CATIA V5 HP-UX

  • Reported component ID

    569102000

  • Reported release

    514

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2005-09-21

  • Closed date

    2005-09-22

  • Last modified date

    2009-06-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 HP-UX

  • Fixed component ID

    569102000

Applicable component levels

  • R516 PSN SP51601

       UP05/12/01 N 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: