APAR status
Closed as unreproducible in next release.
Error description
PART DESIGN / CHANGING THE NAME OF PUBLICATION RESULTS IN LINK LOSS . From CATIA V5, create 2 CATParts -In CATPart1, create any solid -On solid part body, MB3+ Properties and change the name of the body to "test" -Go to Tools+Publication and select body "test" for publishing. -Save CATPart1 -MB3+Copy body "test" -In CATPart2, MB3+Paste Special+As result with link. This should result in a body called "Result of test" -Save CATPart2 -Close CATPart2 -In CATPart1, go to Tools+Publish -From publication list, rename the publication by double clicking in the name field and typing new name. Rename from "test" to "solid" -Save CATPart1 -Reopen CATPart2 -In CATPart2 go to Edit+Links -Notice in the links panel the status now reads "reference not found". There is now no way to repoint or reconnect the copied solid back to the new publish name. .
Local fix
Problem summary
PART DESIGN / CHANGING THE NAME OF PUBLICATION RESULTS IN LINK LOSS PART DESIGN / CHANGING THE NAME OF PUBLICATION RESULTS IN LINK LOSS . From CATIA V5, create 2 CATParts -In CATPart1, create any solid -On solid part body, MB3+ Properties and change the name of the body to "test" -Go to Tools+Publication and select body "test" for publishing. -Save CATPart1 -MB3+Copy body "test" -In CATPart2, MB3+Paste Special+As result with link. This should result in a body called "Result of test" -Save CATPart2 -Close CATPart2 -In CATPart1, go to Tools+Publish -From publication list, rename the publication by double clicking in the name field and typing new name. Rename from "test" to "solid" -Save CATPart1 -Reopen CATPart2 -In CATPart2 go to Edit+Links -Notice in the links panel the status now reads "reference not found". There is now no way to repoint or reconnect the copied solid back to the new publish name. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 14. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 17 GA level . ADDITIONAL INFORMATION: . The problem is also not reproduced at V5R16 GA. . An option of CHANGE PUBLICATION is provided in the EDIT/LINKS panel which allows to change the publication in such cases. GO to Edit/Links Panel after the scenario and then change the Publication. .
APAR Information
APAR number
HD44649
Reported component name
CATIA V5 HP-UX
Reported component ID
569102000
Reported release
514
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-09-21
Closed date
2005-09-22
Last modified date
2009-06-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 HP-UX
Fixed component ID
569102000
Applicable component levels
R516 PSN SP51601
UP05/12/01 N 1000