IBM Support

HD44079: FTA 3D ANNOTATION CANNOT BE CREATED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FTA 3D Annotation cannot be created. This problem
    occurs with specific Settings. The following
    message is given : Invalid data contained in
    document
    By-pass : select OK in the window Fail to create 3D
    annotations, then select Text with Leader icon
    again and select the face : it will work fine
    .
    

Local fix

Problem summary

  • FTA 3D Annotation cannot be created.
    FTA 3D Annotation cannot be created. This problem
    occurs with specific Settings. The following
    message is given : Invalid data contained in
    document
    By-pass : select OK in the window Fail to create 3D
    annotations, then select Text with Leader icon
    again and select the face : it will work fine
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 17 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R15SP05 AND V5R16SP01
    Incident Diagnosis
    The standard used when creating a tolerancing
    set is specified by user with the Tools/Options
    command. The xml file for the standard defined in
    the settings doesn't exist. So, the standard isn't
    correctly set and annotations can't be created.
    Correction Explanation
    We have to check whether the standard specified in
    the settings can be set for 3D annotations. If it isn't
    the case, ISO will be utilized instead.
    Answer and By-Pass
    Choose an available standard with the
    Tools/Options command.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD44079

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    515

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2005-09-06

  • Closed date

    2005-10-26

  • Last modified date

    2009-06-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R515 PSN SP51505

       UP05/12/09 I 1000

  • R516 PSN SP51601

       UP05/12/01 N 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
25 June 2009