APAR status
Closed as program error.
Error description
Impossible to insert an electrical product under a CATProduct with specific CATSettings Scenario: Catia v5r12 SP6 HF12 - First scenario with CATSettings-1 or CATSettings-2 1. Launch CATIA 2. File + Open Product1.CATProduct 3. Select Product1 + MB3 + Components + Existing Component => the window "insert an existing component" opens 4. Select l92910103000a1.CATProduct => error message "Command interrupted" => like picture "command-inter-catia-1.gif" or "command-inter-catia-2.gif" 5. Clic OK => new message "click OK to terminate". . - Second scenario with CATSettings-ref 1. Launch CATIA 2. File + Open Product1.CATProduct 3. Select Product1 + MB3 + Components + Existing Component => the window "insert an existing component" opens 4. Select l92910103000a1.CATProduct => l92910103000a1.CATProduct opens correctly . .
Local fix
Problem summary
Impossible to insert an electrical product under a CATProduct w ith Specific CATSettings Impossible to insert an electrical product under a CATProduct with specific CATSettings Scenario: Catia v5r12 SP6 HF12 - First scenario with CATSettings-1 or CATSettings-2 1. Launch CATIA 2. File + Open Product1.CATProduct 3. Select Product1 + MB3 + Components + Existing Component => the window "insert an existing component" opens 4. Select l92910103000a1.CATProduct => error message "Command interrupted" => like picture "command-inter-catia-1.gif" or "command-inter-catia-2.gif" 5. Clic OK => new message "click OK to terminate". . - Second scenario with CATSettings-ref 1. Launch CATIA 2. File + Open Product1.CATProduct 3. Select Product1 + MB3 + Components + Existing Component => the window "insert an existing component" opens 4. Select l92910103000a1.CATProduct => l92910103000a1.CATProduct opens correctly . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 16 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R15SP1, ON V5R14SP06, ON V5R13SP10 AND ON V5R12SP12. Incident Diagnosis Impossible to insert an electrical product under a CATProduct with Specific CATSettings. A crash occurs in a specific environement. . Correction Explanation Bad pointer test. . Answer and By-Pass no by-pass .
Temporary fix
Comments
APAR Information
APAR number
HD36067
Reported component name
CATIA V5 HP-UX
Reported component ID
569102000
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-03-03
Closed date
2005-04-14
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 HP-UX
Fixed component ID
569102000
Applicable component levels
R512 PSN
UP
R513 PSN
UP
R514 PSN SP51406
UP05/05/13 N 1000