IBM Support

HD34552: BAD BEHAVIOUR OF THE STL FUNCTION WITH A CPT INPUT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as user error.

Error description

  • bad behaviour of the STL function with a CPT input.
    
    
    SCENARIO:
    1- open in V4 the provided model
    2- STL/CREATE, in the parameters panel, key 30
    as maximum size of triangles and 0,05 as
    maximum sag
    3- select the solid sphere then click on YES to
    generate triangulation
    => 960 triangles are generated all around the
    sphere
    4- close the model
    5- open a new model in V4
    6- CLOUD/IMPORT, select ASCII as format then
    indicate the directory where you saved
    the .cgo_ascii file then click on OK
    => 1 cpt is created
    7- POLYGON/CREATE/PGONIZE, select the
    previously imported cpt
    8- key 0,43 as neighborhood size then click on OK
    => nothing happens, I don't think this behaviour is
    normal.
    9- STL/CREATE, in the parameters panel, key 30
    as maximum size of triangles and 0,05 as
    maximum sag
    10- select the cpt then click on YES to generate
    triangulation
    => only 120 triangles are generated. Triangles are
    not created all around the sphere.
    => This behaviour is not normal
    
    
    
    
    
    .
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • THIS PROBLEM IS CONSIDERED AS A USER
    ERROR.
    
    Incident Diagnosis
    No triangle generated by STL function.
    
    
    Correct Application
    A neighbourhood size of 0.43 is too small in
    PGONIZE function. A size of 2 is needed: use
    ANALYSIS function to measure the required
    distance.
    
    
    Documentation Reference
    PGONIZE
    Getting Started
    N/A
    
    .
    

APAR Information

  • APAR number

    HD34552

  • Reported component name

    CATIA V4 AIX

  • Reported component ID

    562610000

  • Reported release

    G24

  • Status

    CLOSED USE

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-02-01

  • Closed date

    2005-09-26

  • Last modified date

    2005-09-26

  • APAR is sysrouted FROM one or more of the following:

    HD34551

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V4 SOLARI

  • Fixed component ID

    562640000

Applicable component levels

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G24"}]

Document Information

Modified date: