APAR status
Closed as program error.
Error description
Abstract: Create Hole with Macro up to Plane . Scenario: 1. Launch the CATIA. 2. Record the macro for ?Hole? creation with below steps. a. Start the recording of macro by Tools > Macro > Start Recording b. Create a new Part, c. Create a Pad with Rectangular sketch. d. Create a hole with 'Up To Plane' option. e. Stop the recording of macro. . 3. Now run the recorded macro. 4. Double click the created hole for edition. 5. Change the option to Blind. . Actual Result: The Depth option is grayed out. Depth can not be changed. . Expected Result: The Depth field should be editable. . This is regression with V5R16 SP5. On this level for the hole created with recorded macro, the Depth for blind option is editable. .
Local fix
Problem summary
Create Hole with Macro up to Plane Abstract: Create Hole with Macro up to Plane . Scenario: 1. Launch the CATIA. 2. Record the macro for ?Hole? creation with below steps. a. Start the recording of macro by Tools > Macro > Start Recording b. Create a new Part, c. Create a Pad with Rectangular sketch. d. Create a hole with 'Up To Plane' option. e. Stop the recording of macro. . 3. Now run the recorded macro. 4. Double click the created hole for edition. 5. Change the option to Blind. . Actual Result: The Depth option is grayed out. Depth can not be changed. . Expected Result: The Depth field should be editable. . This is regression with V5R16 SP5. On this level for the hole created with recorded macro, the Depth for blind option is editable. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP05 . .
Temporary fix
Comments
APAR Information
APAR number
HD85212
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-05-27
Closed date
2009-06-16
Last modified date
2009-07-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN SP51905
UP09/07/31 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
31 July 2009