APAR status
Closed as Permanent restriction.
Error description
FMP: RESULT OF THICKNESS ON FACE IS INCORRECT. . SCENARIO: 1. Open CATPart provided. 2. Expand Complete Oil Pan, Shellable Body.10, Main Shape body and Solid Functional Set.1. 3. Define on Work Object on Solid Functional Set.1. 4. Select Thickness, Local Modifier icon. 5. Select large planar face and give offset in positive Z direction with a value of 3mm. 6. Update. Notice not all the faces offset. This is the problem. . .
Local fix
Problem summary
FMP: RESULT OF THICKNESS ON FACE IS INCORRECT. FMP: RESULT OF THICKNESS ON FACE IS INCORRECT. . SCENARIO: 1. Open CATPart provided. 2. Expand Complete Oil Pan, Shellable Body.10, Main Shape body and Solid Functional Set.1. 3. Define on Work Object on Solid Functional Set.1. 4. Select Thickness, Local Modifier icon. 5. Select large planar face and give offset in positive Z direction with a value of 3mm. 6. Update. Notice not all the faces offset. This is the problem. . .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Incident Diagnosis: When user selects a face to apply thickness one face gets selected. But on same plane, four faces from different features are getting merged. But oviously only one face gets selected and user can not apply thickness to other faces. . Restriction Explanation: It is a face simplification issue. Faces of three external prisms and added feature are overlaped. In CATIA, overlaped faces lying on same geomtrical plane are merged. In order to be able to select all faces user can change there geomtrical plane (by chaning the height). . By-Pass First thickness is created by selecting face of added. Then thickness feature is edited and other desired faces are selected. . .
Temporary fix
Comments
APAR Information
APAR number
HD85123
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-05-22
Closed date
2009-05-28
Last modified date
2009-05-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: