HD83984: CLEANER: CATIA CRASHES WITH CLICK OK TO TERMINATE WHILE RUNNING CATDUA ON CATDRAWING.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SCENARIO:
    1) Start CATIA R19SP3.
    2) Open any of the provided CATDrawing file.
    3) Go to File / Desk.
    4) Right Click on the drawing and select CATDUAV5.
    5) Select Clean or Check.
    6) Click Run.
    .
    OBSERVATION:
    CATIA crashes with following message: Click Ok to
    Terminate
    .
    

Local fix

Problem summary

  • CLEANER: CATIA crashes with click ok to terminate while running
    CATDUA on CATDrawing.
    SCENARIO:
    1) Start CATIA R19SP3.
    2) Open any of the provided CATDrawing file.
    3) Go to File / Desk.
    4) Right Click on the drawing and select CATDUAV5.
    5) Select Clean or Check.
    6) Click Run.
    .
    OBSERVATION:
    CATIA crashes with following message: Click Ok to
    Terminate
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 20 GA LEVEL.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R19SP05.
    .
    INCIDENT DIAGNOSIS:
    CATIA crashes with click ok to terminate while
    running CATDUA on CATDrawing.
    .
    CORRECTION EXPLANATION:
    The algortihm managing an aggregation issue
    between a Drawing and its Sheet crashes when
    there are some very specific aggregation issues
    involving a Drawing. The algorithm is modified so
    that problem is not produced anymore.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD83984

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-08

  • Closed date

    2009-05-18

  • Last modified date

    2009-07-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R519 PSN SP51905

       UP09/07/31 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
31 July 2009