Error description
PART:Multi-Section Solid gives error message for different closing points in special case. . SCENARIO: 0. Start V5- Workbench: Part Design 1. Open the supplied CATPart 2. Select the command: Multi-section Solid 3. Select Sketch1 in the tree 4. Select Sketch2 in the tree 5. Mark the line 1 with sketch1 in the menu and use the right mouse button with Replace closing point and select Point1_1_2 6. Mark the line 2 with sketch2 in the menu and use the right mouse button with Replace closing point and select Point2_1 7. Switch to Coupling and select the Sections coupling:Vertices 8. Push the Add button and then select in the tree Point1_1_2 and Point2_1, Point1_1_2 and Point2_2 Point1_3_4 and Point2_3,Point1_3_4 and Point2_4 9. Use Preview An error is thrown Multi-Sections Solid.1 - Loft operator: Impossible to homogenize the sections before the loft computation For detail scenario please refer the avi file attached. . RESULT: An error is thrown Multi-Sections Solid.1 - Loft operator: Impossible to homogenize the sections before the loft computation. Solid is not created . .
Local fix
Problem summary
PART:Multi-Section Solid gives error message for different clos ing points in special case PART:Multi-Section Solid gives error message for different closing points in special case. . SCENARIO: 0. Start V5- Workbench: Part Design 1. Open the supplied CATPart 2. Select the command: Multi-section Solid 3. Select Sketch1 in the tree 4. Select Sketch2 in the tree 5. Mark the line 1 with sketch1 in the menu and use the right mouse button with Replace closing point and select Point1_1_2 6. Mark the line 2 with sketch2 in the menu and use the right mouse button with Replace closing point and select Point2_1 7. Switch to Coupling and select the Sections coupling:Vertices 8. Push the Add button and then select in the tree Point1_1_2 and Point2_1, Point1_1_2 and Point2_2 Point1_3_4 and Point2_3,Point1_3_4 and Point2_4 9. Use Preview An error is thrown Multi-Sections Solid.1 - Loft operator: Impossible to homogenize the sections before the loft computation For detail scenario please refer the avi file attached. . RESULT: An error is thrown Multi-Sections Solid.1 - Loft operator: Impossible to homogenize the sections before the loft computation. Solid is not created . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE R19 SP05 AND R20 GA LEVEL. Incident Diagnosis: Sections homogenization fails in particular case of coupling lines intersecting one another on section closure point . Correction Explanation: There was a confusion with closure point for the intersection point of coupling guide/section.This behavior has been corrected. .
Temporary fix
Comments
APAR Information
APAR number
HD83774
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-01
Closed date
2009-05-04
Last modified date
2009-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 May 2009