APAR status
Closed as Permanent restriction.
Error description
Machining NCReview / Tool shape is created partially with Craete Geometry function. Scenario: 1.Open/"Sample.CATProcess" 2. /Tool Change.8 T4 Press right mouse button /ToolPath/ Select Geometry creation 3.Geometry Creation BOX is open 3-1.Destination : Part5 3-2.Type : Points and Tools 3-3.Selection : Whole Tool Path 3-4.Press Apply . Result: An error occurs, and shape is not made completely. Excepted Result : Tool shape in Geometry create it should be completely made. .
Local fix
Problem summary
Machining NCReview / Tool shape is created partially with Craet e Geometry function. Machining NCReview / Tool shape is created partially with Craete Geometry function. Scenario: 1.Open/"Sample.CATProcess" 2. /Tool Change.8 T4 Press right mouse button /ToolPath/ Select Geometry creation 3.Geometry Creation BOX is open 3-1.Destination : Part5 3-2.Type : Points and Tools 3-3.Selection : Whole Tool Path 3-4.Press Apply . Result: An error occurs, and shape is not made completely. Excepted Result : Tool shape in Geometry create it should be completely made. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA INCIDENT DIAGNOSIS Tool shape is created partially with Create Geometry function due to self intersecting geometry. RESTRICTION EXPLANATION In the Create Geometry command, the tool Geometries are created using the revolution surface operator. . The profile of the tool contains an edge whose length is equal to the geometric tolerance (0.001 mm = 1 micron). . The revolution surface operator considers such a profile as self intersecting. . In such cases the creation of the revolution surface operator is not guaranteed. Hence the tool geometry gets created at some locations while at others it does not create. By-Pass . If the tool profile is such that the length of the edge is larger than the geometric tolerance (> 1 micron), the revolution surface operator will work correctly. This can be achieved by increasing the value of db from 0.5 mm to 0.502 mm. .
Temporary fix
Comments
APAR Information
APAR number
HD83717
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-30
Closed date
2009-06-11
Last modified date
2009-06-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: