Error description
Machining (NCReview): Division fails to execute from a PP instruction. . 1. Start CATIA 2. Open the provided CATProcess. 3. Expand the process tree to display the machine operations. 4. From the manufacturing Process remove the tool paths. 5. From the manufacturing Process compute the tool paths. 6. Expand the first HEAD/4 machine operation and the last HEAD/4 machine operation. 7. From the first Head/4 machine operation open instruction 38 and Note the expression. 8. Open instruction 30. Note the expression has added division by 2 9. Open instruction 31 Note the expression has added multiplication by 2 10. Check instructions 39, 36 and 37 11. Generate NC Code interactively. Select APT file and execute. RESULT: The division problem fails to be executed. EXPECTED RESULT: It is expected that the division problem will be executed 12. Generate NC Code interactively. Select CLF file and execute. RESULT: The division problem fails to be executed. EXPECTED RESULT: It is expected that the division problem will be executed .
Local fix
Problem summary
Machining (NCReview): Division fails to execute from a PP instr uction. Machining (NCReview): Division fails to execute from a PP instruction. . 1. Start CATIA 2. Open the provided CATProcess. 3. Expand the process tree to display the machine operations. 4. From the manufacturing Process remove the tool paths. 5. From the manufacturing Process compute the tool paths. 6. Expand the first HEAD/4 machine operation and the last HEAD/4 machine operation. 7. From the first Head/4 machine operation open instruction 38 and Note the expression. 8. Open instruction 30. Note the expression has added division by 2 9. Open instruction 31 Note the expression has added multiplication by 2 10. Check instructions 39, 36 and 37 11. Generate NC Code interactively. Select APT file and execute. RESULT: The division problem fails to be executed. EXPECTED RESULT: It is expected that the division problem will be executed 12. Generate NC Code interactively. Select CLF file and execute. RESULT: The division problem fails to be executed. EXPECTED RESULT: It is expected that the division problem will be executed .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. . Incident Diagnosis Division fails for the Design Parameters because of the way they are defined with a parenthesis. Correction Explanation Problem is fixed with the check for the design parameters with parentheses. .
Temporary fix
Comments
APAR Information
APAR number
HD83530
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-24
Closed date
2009-06-16
Last modified date
2009-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN
UP