APAR status
Closed as Permanent restriction.
Error description
PD:Impossible to create 3D line with corner of a sketch. . SCENARIO: 1. Start CATIA V5 2. Open the supplied CATPart 3. Try to create a line from the point (point 2) to the corner of sketch.1 4. An error message is thrown saying: The selected element is a non connex element.Input element Sketch.1\Vertex has to be connex.Use another element, or extract connex entity with NEAR operator. . RESULT: Line is not created from point to the corner of the sketch . .
Local fix
Problem summary
PD:Impossible to create 3D line with corner of a sketch PD:Impossible to create 3D line with corner of a sketch. . SCENARIO: 1. Start CATIA V5 2. Open the supplied CATPart 3. Try to create a line from the point (point 2) to the corner of sketch.1 4. An error message is thrown saying: The selected element is a non connex element.Input element Sketch.1\Vertex has to be connex.Use another element, or extract connex entity with NEAR operator. . RESULT: Line is not created from point to the corner of the sketch . .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA ncident Diagnosis: The design leads to a Generic Naming ambiguity. Two elements have the same name that identify them in the system. The 2 points cannot be discriminated during selection. . Restriction Explanation: 2 subelements (endpoints of the line) coming from the sketches have the same inner naming (the same ID).This is generic naming ambiguity. It happens because both these points share the same topological neighbours (the semi-circle and the line). So during selection both (the 2 subelements with same ID) are selected at the same time. The behavior is a restriction in CATIA. The selection cannot differentiate the end points as both the endpoints have a single generic name in this case. . By-Pass: Following are 2 By-Passes recommended : A. Step1) Create a Point with type as 'On curve' at the vertex (corner) of the sketch. Step2) Then create a line between this point and point.2.This will solve the naming ambiguity and a line can be constructed . B. Break the line in the sketch into 2 parts.with the Break command. This will solve the naming ambiguity and a line can be constructed. .
Temporary fix
Comments
APAR Information
APAR number
HD83372
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-18
Closed date
2009-03-26
Last modified date
2009-03-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
26 March 2009