  • Closed as Permanent restriction.

Error description

  • PD:Impossible to create 3D line with corner of a
    sketch.
    .
    SCENARIO:
    1. Start CATIA V5
    2. Open the supplied CATPart
    3. Try to create a line from the point (point 2) to
    the corner of sketch.1
    4. An error message is thrown saying: The selected
    element is a non connex element.Input element
    Sketch.1\Vertex has to be connex.Use another
    element, or extract connex entity with NEAR
    operator.
    .
    RESULT:
    Line is not created from point to the corner of the
    sketch .
    .
    

Local fix

Problem summary

  • PD:Impossible to create 3D line with corner of a sketch
    PD:Impossible to create 3D line with corner of a
    sketch.
    .
    SCENARIO:
    1. Start CATIA V5
    2. Open the supplied CATPart
    3. Try to create a line from the point (point 2) to
    the corner of sketch.1
    4. An error message is thrown saying: The selected
    element is a non connex element.Input element
    Sketch.1\Vertex has to be connex.Use another
    element, or extract connex entity with NEAR
    operator.
    .
    RESULT:
    Line is not created from point to the corner of the
    sketch .
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    ncident Diagnosis:
    The design leads to a Generic Naming ambiguity.
    Two elements have the same name that identify
    them in the system. The 2 points cannot be
    discriminated during selection.
    .
    Restriction Explanation:
    2 subelements (endpoints of the line) coming from
    the sketches have the same inner naming (the
    same ID).This is generic naming ambiguity. It
    happens because both these points share the same
    topological neighbours (the semi-circle and the
    line). So during selection both (the 2 subelements
    with same ID) are selected at the same time.
    The behavior is a restriction in CATIA. The
    selection cannot differentiate the end points as both
    the endpoints have a single generic name in this
    case.
    .
    By-Pass:
    Following are 2 By-Passes recommended :
    A.
    Step1) Create a Point with type as 'On curve' at the
    vertex (corner) of the sketch.
    Step2) Then create a line between this point and
    point.2.This will solve the naming ambiguity and a
    line can be constructed
    .
    B.
    Break the line in the sketch into 2 parts.with the
    Break command. This will solve the naming
    ambiguity and a line can be constructed.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD83372

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-03-18

  • Closed date

    2009-03-26

  • Last modified date

    2009-03-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
26 March 2009