IBM Support

HD82675: CMP: SOME DATA LOST WHEN CREATING A PVR FROM A PVS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • Some data lost when creating a PVR from a PVS scenario:
    1- Start VPMNav and connect it to the server
    2- Display a specific PRC
    3- Expand and select all the instances of the PRC
    4- Load the instance in Context
    -> Result: All the data are well displayed in Catia
    5- Close  Product structure
    6- Select the PRC and create an attribute Filter with
       PartNumber=*
    7- Create a PVR on this filter structure
    -> In this PVR some parts have disappeared.
       Without the filter, all files are well loaded.
    .
    

Local fix

Problem summary

  • CMP: Some data lost when creating a PVR from a PVS
    Some data lost when creating a PVR from a PVS
    scenario:
    1- Start VPMNav and connect it to the server
    2- Display a specific PRC
    3- Expand and select all teh instances of the PRC
    4- Load the instance in Context
    --> Result all the data are well displayed in Catia
    5- Close  Product structure
    6- Select the PRC and create an attribute Filter with
    PArtNumer=*
    7-Create a PVR on this filter structure
    --> In this PVR some parts have disappeared.
    Without the filter , all files are well loaded.
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON ENOVIA
    VERSION 5 RELEASE 18.
    THIS PROBLEM IS NOT REPRODUCIBLE ON ENOVIA
    VERSION 5 RELEASE 20 GA AND ON V5R19SP04
    LEVEL.
    .
    .
    

APAR Information

  • APAR number

    HD82675

  • Reported component name

    ENOVIA V5 VPM N

  • Reported component ID

    569151400

  • Reported release

    518

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-02-26

  • Closed date

    2009-03-06

  • Last modified date

    2009-03-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA V5 VPM N

  • Fixed component ID

    569151400

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: