APAR status
Closed as documentation error.
Error description
IGES:About toletance for IGES import . SCENARIO: 1) Launch CATIA V5R17SP8. 2) Select Tools - Options. 3) Select Options ? General ? Compatibility ? IGES tab. 4) It is possible to set Tolerance at Import ? Join. 5) Launch CATIA V5R18SP6. 6) Operate step2-3. . PROBLEM: The option "IGES-Join-Tolerance" is lost from R18. Cannot confirm the tolerance when importing IGES data. .
Local fix
Problem summary
IGES:About toletance for IGES import IGES:About toletance for IGES import . SCENARIO: 1) Launch CATIA V5R17SP8. 2) Select Tools - Options. 3) Select Options ? General ? Compatibility ? IGES tab. 4) It is possible to set Tolerance at Import ? Join. 5) Launch CATIA V5R18SP6. 6) Operate step2-3. . PROBLEM: The option "IGES-Join-Tolerance" is lost from R18. Cannot confirm the tolerance when importing IGES data. .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN THE DOCUMENTATION DELIVERED WITH CATIA VERSION 5 RELEASE 20 GA LEVEL. Incident Diagnosis: About toletance for IGES import . Documentation Reference MULTICAx IGES Plug-in Customizing IGES . MODIFICATION: Following has been updated in documentation: Join: Select the option Join surfaces of the model if you want to join the surfaces of your IGES model into a shell. If this option is active, the software will try to knit the surfaces from an importable file into a shell, even if the file contains Groups (402), with the merging tolerance, i.e. the input file resolution (from field #19 of the file Global section), limited between the modeler tolerance and 100 x the modeler tolerance. The modeler tolerance depends on the current session scale. .
Temporary fix
Comments
APAR Information
APAR number
HD82441
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-02-19
Closed date
2009-02-27
Last modified date
2009-02-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
27 February 2009