HD81732: FTA / DIMENSIONS DO NOT MOVE ALONG WITH THE GEOMETRY AFTER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • FTA / Dimensions do not move along with the
    geometry after filtering.
    .
    SETTINGS:
    Part Infrastructure must be set to Manual Update in
    Tools/Options/Infrastructure/Part
    Infrastructure/Upadate select as Manual.
    .
    SCENARIO:
    0) Start CATIA.
    1) Open R19sp2 Move to origin with FTA.CATPart
    2) Click Part to Part command
    3) Set the following options ?
    - Keep Product Properties
    - Keep Colors and Attributes of subelements
    - Keep annotations
    4) Click OK
    = We now have a new part Move to
    origin_AllCATPart.CATPart
    5) Place Compass on face of solid.
    6) While holding CTRL, select Solid.1, Point.1, and
    Axis System.1
    7) Right click the red dot on the Compass and
    select Edit
    = Parameters for Compass manipulation window is
    displayed
    8) Enter ?0? in all values
    9) Click Apply
    10) Click Close
    11) Right click on un-updated features.
    .
    PROBLEM:
    Annotations will move when we update the
    Annotation Set.1
    (1) After creating the *ALL.CATPart file from the
    original one, the solid can be moved, but the FTA
    Dimensions do not.
    (2) They also appear out of sync in R19SP2
    .
    EXPECTED RESULT:
    (1) FTA dimensions move with the geometry
    (2) FTA dimensions remain in sync.
    .
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM HAS BEEN FOUND TO BE ANOTHER
    SYMPTOM OF THE PROBLEM REPORTED IN
    HD80596. OR THE ANSWER MADE
    FOR THIS DUPLICATE APAR APPLIES ALSO TO THE
    CURRENT PROBLEM.
    Incident Diagnosis:
    PDF: FTA Dimensions do not move along with the
    geometry after filtering.
    .
    Correct Application:
    To make a dimension to follow the geometry, the
    Constant offset between dimension line and
    geometry option should be set before creating the
    dimension(in the original model).
    .
    Documentation:
    Tools\Options\MD\FTA\Dimension\Constant offset
    between dimension line and geometry
    Defines whether the distance between the created
    dimension and the geometry remains the same
    when you move the geometry or not. By default,
    this option is not selected.
    .
    Documentation Reference
    http://dsdoc/doc19/online/CATIAfr_C2/fdtugCATIAf
    rs.htm
    Customizing Dimension
    .
    Note- To get the correct results the dimensions has to be
    recreated after applying the option for constant offset.
    .
    

APAR Information

  • APAR number

    HD81732

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED DUA

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-01-27

  • Closed date

    2009-02-27

  • Last modified date

    2009-02-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
27 February 2009