APAR status
Closed as program error.
Error description
ASD:Compass rotation increments not being honored . SCENARIO: 1) Open any assembly that contains a sub assembly 2) Set the compass rotation increments to 90 degrees 3) Place (or set snap) and rotate a part within the assembly. Note that the part honors the 90 degree setting. 4) Open one of the sub assemblies from the higher level assembly in a New Window. 5) Set the compass rotation increments to 30 degrees 6) Place (or set snap) and rotate a part within the sub assembly. Note that the part honors the 30 degree setting. 7) Return to the window with the higher level asm and place (or set snap) on a part. Rotate the part and note that the part does not honor the 30 degree setting but rather is still honoring the 90 degree setting. . PROBLEM: In the higher level assembly the parts are rotating in increments of 90 degrees but if you open the compass editor the setting is 30 degrees. . EXPECTED RESULT: Compass rotation should be honored. .
Local fix
Problem summary
ASD:Compass rotation increments not being honored ASD:Compass rotation increments not being honored . SCENARIO: 1) Open any assembly that contains a sub assembly 2) Set the compass rotation increments to 90 degrees 3) Place (or set snap) and rotate a part within the assembly. Note that the part honors the 90 degree setting. 4) Open one of the sub assemblies from the higher level assembly in a New Window. 5) Set the compass rotation increments to 30 degrees 6) Place (or set snap) and rotate a part within the sub assembly. Note that the part honors the 30 degree setting. 7) Return to the window with the higher level asm and place (or set snap) on a part. Rotate the part and note that the part does not honor the 30 degree setting but rather is still honoring the 90 degree setting. . PROBLEM: In the higher level assembly the parts are rotating in increments of 90 degrees but if you open the compass editor the setting is 30 degrees. . EXPECTED RESULT: Compass rotation should be honored. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. . INCIDENT DIAGNOSIS: When several windows are opened, compass values were transmitted from one window user interface to the others however they are not taken into account in the compass manipulations. Each window owns its compass but the values were stored in the compass panel as static variables, therefore each panel was not having its own values. . CORRECTION EXPLANATION: The correction has been done by removing the static declarations so that each panel will have its own values and values will not be transmitted from one window to other window. .
Temporary fix
Comments
APAR Information
APAR number
HD80937
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-12-23
Closed date
2009-07-10
Last modified date
2009-07-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
10 July 2009