  • Closed as program error.

Error description

  • Issue:
    Crash occurs at PVR creation for a specific structure.
    The step-by-step scenario is:
    1- Search PVS
    2- Expand structure up to the desired assembly
      (3rd level)
      PRC (BS1145)
      |___ASSY1
      |__ASSY2
      |__ASSY3 (PVR is created at that level)
    3- Click on Create a Product View Result icon
    4- Enter PVR name and click OK
    
    Two scenarios have been replayed and both are failing.
    In the first case (A), the PVS is linked to a
    DYNAMIC configuration handler.
    In the second case (B), the PVS is linked to a STATIC
    configuration handler.
    Both configuration handlers are really similar, except the
    static or dynamic nature of the configuration handler. The same
    number of actions/modifications is included in their definition.
    Detailed information about the CH:
    - Total number of actions included in CH : 685 actions
    - Total number of modifications included in CH : 2152
      modifications
    The cases A & B are performed on the same structure.
    Detailed information about the structure:
    - Number of actions used in the structure configuration : 31
      actions
    - Number of modifications used in the structure configuration :
      246 modifications
    - Number of instances by level. The PRC is the level zero.
    LEVEL COUNT(*)
    ------ -------
    0 1
    1 2
    2 288
    3 3415
    4 5308
    5 1698
    6 151
    - Number of instances in assembly used to create PVR
    (ASSY3): 27 detail children instances (flat) Vault File Size
    70037 Bytes
    .
    

Local fix

Problem summary

  • CRASH AT PVR CREATION
    Issue:
    Crash occurs at PVR creation for a specific
    structure. The step-by-step scenario is:
    1- Search PVS
    2- Expand structure up to the desired assembly
    (3rd level)
    PRC (BS1145)
    |___ASSY1
    |__ASSY2
    |__ASSY3 (PVR is created
    at that level)
    3- Click on Create a Product View Result icon
    4- Enter PVR name and click OK
    Two scenarios have been replayed and both are
    failing. In the first case (A), the PVS is linked to a
    DYNAMIC configuration handler. In the second case
    (B), the PVS is linked to a STATIC
    configuration handler.
    Both configuration handlers are really similar,
    except the static or dynamic nature of the
    configuration handler. The same number of
    actions/modifications is included in their definition.
    Detailed information about the CH:
    - Total number of actions included in CH : 685
    actions
    - Total number of modifications included in CH :
    2152 modifications
    The cases A & B are performed on the same
    structure. Detailed information about the structure:
    - Number of actions used in the structure
    configuration : 31 actions
    - Number of modifications used in the structure
    configuration : 246 modifications
    - Number of instances by level. The PRC is the
    level zero.
    LEVEL COUNT(*)
    ------ -------
    0 1
    1 2
    2 288
    3 3415
    4 5308
    5 1698
    6 151
    - Number of instances in assembly used to create
    PVR
    (ASSY3): 27 deatil children instances (flat) Vault
    File Size 70037 Bytes
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON ENOVIA
    VERSION 5 RELEASE 19 SP04 LEVEL.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP08
    Corrected
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD79472

  • Reported component name

    ENOVIA V5 VPM H

  • Reported component ID

    569102400

  • Reported release

    518

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-11-07

  • Closed date

    2009-02-06

  • Last modified date

    2009-02-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA V5 VPM H

  • Fixed component ID

    569102400

Applicable component levels

  • R518 PSN SP51808

       UP09/02/24 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"","label":""}}]