IBM Support

HD78874: DRAFTING(GENDRAFT)/ UNABLE TO COMPUTE SOME SECTION AND BREAKOUT VIEWS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • DRAFTING(GENDRAFT)/ UNABLE TO COMPUTE
    SOME SECTION AND BREAKOUT VIEWS.
    .
    SCENARIO:
    .
    Start CATIA
    1.Open the CATPart and The CATDrawing.
    2. In the CATDrawing window,
    3. Click Section View  command and create section
    view from the Front View In the Drawing
    .
    RESULTS OBTAINED:.
    Section view is not created. an error message is
    Shown:
    "Intersection computation has failed for body '' of
    part. "
    .
    ADDITIONAL INFORMATION:
    .
    Same error is found if the Breakout View is created
    from the Front View.
    .
    EXPECTED RESULTS:
    .
    The section view  and breakout view should be
    created without error.
    .
    .
    

Local fix

Problem summary

  • DRAFTING(GENDRAFT)/ UNABLE TO COMPUTE SOME SECTION AND BREAKOUT
    VIEWS
    DRAFTING(GENDRAFT)/ UNABLE TO COMPUTE
    SOME SECTION AND BREAKOUT VIEWS.
    .
    SCENARIO:
    .
    Start CATIA
    1.Open the CATPart and The CATDrawing.
    2. In the CATDrawing window,
    3. Click Section View  command and create section
    view from the Front View In the Drawing
    .
    RESULTS OBTAINED:.
    Section view is not created. an error message is
    Shown:
    "Intersection computation has failed for body '' of
    part. "
    .
    ADDITIONAL INFORMATION:
    .
    Same error is found if the Breakout View is created
    from the Front View.
    .
    EXPECTED RESULTS:
    .
    The section view  and breakout view should be
    created without error.
    .
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    INCIDNET DIAGNOSIS:
    UNABLE TO COMPUTE SOME SECTION AND
    BREAKOUT VIEWS.
    .
    EXPLANATION:
    .
    Drafting failure due to incorrect geometry in input
    model.
    .
    RESTRICTION EXPLANATION:
    Drafting fails due to a failure in boolean operation.
    Boolean fails due to incorrect input body. The data
    are not provided with the historic of construction
    (but only datum geometry). The problem is may be
    corrected on the current level of code after
    upgrading feature fillet.
    By-Pass
    CATPart and CATDrawing attached.
    Remove the fillet surface that is incorrect by a fill
    surface.
    The Drawings can now be performed successfully.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD78874

  • Reported component name

    CATIA V5 SOLARI

  • Reported component ID

    569104000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-10-17

  • Closed date

    2008-12-03

  • Last modified date

    2008-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 December 2008